Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1297895.1
Update Date:2011-04-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1297895.1 :   Sun SPARC(R) Enterprise Mx000 (OPL) Servers: How to reset Mx000 XSCF password  


Related Items
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>OPL Servers
  •  




In this Document
  Goal
  Solution
  References


Applies to:

Sun SPARC Enterprise M5000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun SPARC Enterprise M3000 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M4000 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later    [Release: N/A and later]
Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

In some cases, the customer may have forgotten the XSCF user name or password. This document will
tell the customer how to recover it.

Solution

The following procedure to reset a lost password.

---
1. Connect the administrative console to the serial port using the serial cable that shipped with the server.
2. Configure the settings on the administrative console.  The console should have the following settings:
  • Baud rate: 9600 bps
  • Data length: 8 bit
  • Parity: None
  • Stop: 1 bit
  • Flow control: None
  • Delay: Except for 0
3. When the login prompt appears, enter default for the login name:
  • Default user account: default
  • The user privileges are useradm, platadm.
  • Default password:
The default password is not input directly on the keyboard. Instead, after the default user account is input, the mode switch of the operator panel is operated as follows.
  • If Locked, change to Service. (Or if Service, change to Locked)
  • Press return. Keep the status for more than 5 seconds.
  • Change to Locked. (Or change to Service)
  • Press return.
This mode switch operation is done within one minute. When one minute is passed, the authentication timeout occurs.
Sample
login: default
Change the panel mode switch to Service and press return...
(Operation : Locked state -> Service -> Return)
Leave it in that position for at least 5 seconds. Change the panel
mode switch to Locked, and press return...
(Operation : Wait more than 5 seconds -> Service state ->
Locked -> Return)
XSCF>


4.Use the showuser -l command to confirm your current user info.
Sample:

User Name: xxxxx
UID: 100
Status: Enabled
Minimum: 0
Maximum: 99999
Warning: 7
Inactive: -1
Last Change: Mar xx, 20xx
Password Expires: Never
Password Inactive: Never
Account Expires: Never
Privileges: useradm
platadm
fieldeng


5.Use the deleteuser command to delete your forgotten user or create a new user for XSCF

6. Using the commands below,  set user account, password and privileges.

XSCF> adduser xxxxx
XSCF> password xxxxxxxx
XSCF> setprivileges xxxxxx

7. You can use the exit command to logout and try your new user account.
8. Done.

References

http://download.oracle.com/docs/cd/E19855-01/821-2797-10/821-2797-10.pdf

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.