Solution Type Technical Instruction Sure Solution 1297895.1 : Sun SPARC(R) Enterprise Mx000 (OPL) Servers: How to reset Mx000 XSCF password
In this Document
Applies to:Sun SPARC Enterprise M5000 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun SPARC Enterprise M3000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M4000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M9000-32 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalIn some cases, the customer may have forgotten the XSCF user name or password. This document willtell the customer how to recover it. SolutionThe following procedure to reset a lost password.--- 1. Connect the administrative console to the serial port using the serial cable that shipped with the server. 2. Configure the settings on the administrative console. The console should have the following settings:
Sample 4.Use the showuser -l command to confirm your current user info. Sample: 5.Use the deleteuser command to delete your forgotten user or create a new user for XSCF 6. Using the commands below, set user account, password and privileges. XSCF> adduser xxxxx 7. You can use the exit command to logout and try your new user account. 8. Done. Referenceshttp://download.oracle.com/docs/cd/E19855-01/821-2797-10/821-2797-10.pdfAttachments This solution has no attachment |
||||||||||||
|