Solution Type  Technical Instruction Sure

Solution  1163913.1 :   SL3000 - SCSI/FC Mode - Unable to Modify Active Cells in SL Console With 2.30/2.35 and 4.40/4.45 SLConsole Codes  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Storage SL3000 Modular Library System - Version: Not Applicable and later   [Release: NA and later ]
Information in this document applies to any platform.

Goal

SCSI/FC Mode - Unable to modify active cells in SL Console with 2.30/2.35 and 4.40/4.45 SL Console codes.

Solution

Workaround to this problem.  Partitioned libraries are not affected.

a. Change SL3000 from FC/SCSI to HLI and click APPLY
b. Make the necessary changes in the active cells then click APPLY
c. Change back to FC/SCSI mode and click APPLY

A permanent fix will be available in a future release of microcode.  TBD