Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1139889.1 : SL3000 - Information That Was Not Included in 2.81 Release Notes
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun Storage SL3000 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. GoalAdditional information concerning SL3000 2.81 microcode release.Solution1. With 2.81 microcode, SILKs keys have been wiped out and need to be re-generated.2. After a library reboot, the SDP Alias ends up getting changed. An unexpected reset on Port-1A alias will occur. -Contact Level 2 Tape Hardware Support to acquire a script to change the SDP alias back to the correct alias. 3. 2.81 microcode does not support the 'config complexid set' command for alias re-configuration. 4. Local Support will need to engage T3 Support to assist in re-configuration of the SDP Port alias once a library reboot has taken place. 5. A third reboot will be required after port 1A has been reconfigured. Upgrading to 2.81 microcode will require 3 reboots. Attachments This solution has no attachment |
||||||||||||
|