Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1110439.1
Update Date:2010-06-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1110439.1 :   How To Get An RTD Out Of Maintenance Mode  


Related Items
  • Sun StorageTek Virtual Tape Control Software (VTCS)
  •  
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage Software>Mainframe Software
  •  
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Storage Virtual Tape Control System (VTCS) - Version: All Versions and later   [Release: All Releases and later ]
Sun Storage VSM System - Version: Not Applicable and later    [Release: NA and later]
IBM z/OS on System z

Goal

How to get an RTD out of maintenance mode.
How to recover an RTD that is in maintenance mode.
How to bring an RTD from maint mode.

Solution

FSC73D8 indicates that a suspect broken RTD has been detected.

Internal instructions
1. Connect to the failing VTSS subsystem and check the RTD Status.
2. If RTD is found Online, skip to Internal Step 6.
3. If RTD is found Offline Maintenance Mode, skip to Internal Step 5.
4. If RTD is found Offline Undefined Mode, please review <>.
5. Contact customer and check the status of the RTD problem. If the RTD is still in maintenance mode, have the customer do the following:

If an RTD is found to be in maintenance mode please do the following:
1. Issue the command:  VT VARY RTD(xxxx) OFF -- where xxxx is the RTD address
The following messages will be displayed:
SLS5010I Vary submitted to VSM system
SLS5011I Vary - Device xxxx offline
SLS5013I Vary completed (0)
2. Verify the RTD is OFFLINE by issuing the following command:  VT D RTD
3. Once offline, issue this command:  VT VARY RTD(xxxx) ON  -- where xxxx is the RTD address
The following messages will be displayed:
SLS5010I Vary submitted to VSM system
SLS5011I Vary - Device xxxx online
SLS5013I Vary completed (0)
SLS6634I RTD xxxx available for use
4. Verify the RTD is ONLINE by issuing this command:  VT D RTD

When issuing the above commands, please prefix the command with the HSC identifier defined to your system. For example, the symbol '#' can be defined as the identifier and a sample command would be #VT D RTD.

6. Verify with the customer the RTD problem has been resolved.
7. Request customer's permission to close the SR.
8. If the RTD is still OFFLINE - Dispatch local CSE for service.

Previously Published As:  223469 (IBIS)
FSC73D8, VSM, VTCS

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback