  Goal
  Solution


Applies to:

Sun Storage 6180 Array
Sun Storage Common Array Manager (CAM) - Version: 6.5 and later    [Release: 6.0 and later]
All Platforms

Goal


To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, Storage Disk 6000 and 2000 Series RAID Arrays Community.


This article documents Sun Storage 6180 Array's components firmware baseline bundled in each corresponding CAM release and patched versions.

This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility.

For instructions to download CAM, please refer to <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches.

Solution

Sun Storage 6180 Firmware
CAM release Patch Controller Expansion
Firmware NVSRAM CSM200
CAM release Patch Firmware NVSRAM CSM200
Controller Expansion

No Support
1.x
2.x
5.x
6.0.x
6.1.x
6.2.x
6.4.x
6.5.0.10
07.60.18.10 N49XX-760843-003 98C5
6.5.0.11 141581-01 CAM core patch for Windows only, fix for J4500 fw update failure.
6.5.0.x controlled (07.60.18.10) N49XX-760843-039 a
6.5.0.x 142798-01
142799-01
142800-01
Firmware patch for 2500 ExmoorM2; J4000 Seagate drive SU0E.
6.5.0.13 141580-02
141581-02
141582-02
CAM core patch -02; various fixes.
6.5.0.13 142798-02
142799-02
142800-02
Seagate firmware SU0F for J4200/4400, includes SU0E (retained for J4500) and ExmoorM2 for 2500 from firmware patch -01.
6.6.0.11 b
07.60.18.13 N49XX-760843-004 98D0
6.6.0.12 b 141474-01b
141475-01 
141476-01 
CR6935284 CAM BUI host types do not match array hostregion.
6.6.0.12 143759-01
143760-01
143761-01
07.60.36.10
6.7.0.12
07.60.36.13 N49XX-760843-004 98D3
6.7.0.13 144861-01 CAM core patch for Windows only. Fixes CR6972298 Win2008 undefined constant; and CR6968739 J4410 reporting incorrect chassis serial number.
6.7.0.x 145965-01
145966-01
145967-01
F5100 LF1.0-ERIE firmware.
6.7.0.x 145965-02
145966-02
145967-02
07.60.53.10 Seagate drives firmware fixes for 6000/2500/J4000; 6000/2500 controller firmware fixes. Includes all previous fixes in 14596[567]-*.
6.7.0.x 145965-03
145966-03
145967-03
07.60.53.10 For F5100 FMOD firmware fixes FMODs zombie during db restore operation. Includes all previous fixes in 14596[567]-*.
Note "controlled" items are not publicly available and are provided on case-by-case basis upon consultation with backline and/or engineering.
a Temporary fix for CR6704575 PFA issue.
b CAM 6.6.0.11 host types do not match array's host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780. This may result in either new mappings selecting the wrong host region, or user confused by the display and change existing mappings which was correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was specifically released to resolve this bug.

 