Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1022239.1
Update Date:2011-04-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1022239.1 :   VTL - Does VTL Console GUI run on Windows 7?  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
278150


Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 to 4.0 - Build 1221   [Release: 4.0 to 4.0]
All Platforms

Goal

Does the VTL Console GUI run on Windows 7?

Solution

VTL Console Builds 1656 and later do run on Windows 7.

Earlier builds (1221, 1323, 1590 and 1636) have not been certified for running on Windows 7.

Note: Builds earlier than 1656 were attempted and the VTL Console did not function properly.  Code changes are required.  There are no plans to certify for VTL Builds 1636 or earlier.



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback