Solution Type Technical Instruction Sure Solution 1022229.1 : ATR-0986-0987 V880 - V890 FlashPROM FW Update
PreviouslyPublishedAs 277735 Description *DISPATCH INSTRUCTIONS* WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) V880 - V890 Product Training DELIVERY REQUIREMENT: Schedule for immediate replacement within contractual terms. TASK COMPLEXITY: 3 This ATR solution has an attached video. Click here to view the video and associated materials. Steps to Follow *FIELD ENGINEER INSTRUCTIONS* PROBLEM OVERVIEW: WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Customer should take normal precautions to backup data, notify users
of maintenance and that the system will be powered down. Customer
should conduct an orderly software system shutdown. The installation shall comprise of the following steps 1) Determine system's current Flash PROM firmware (OBP) revision. /usr/sbin/prtconf -V From OBP; .version 2) Compare current OBP revision with available OBP revision. 3) If current OBP revision is lower than the If it is not already located within the root partition then move it to /. b) As root, exit the OS such that the system returns to OBP: # halt ok c) Jumper J1104 is factory-set so that the flash PROM is write-enabled. 5) Running the Flash PROM Utility c) The system should now display the OBP "ok" prompt. ok boot disk /flash-update-SunFire880 6) Verify successful Flash PROM Update 7) Restore system and resume operations OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: PARTS NOTE: REFERENCE INFORMATION: Attachments This solution has no attachment |
||||||||||||
|