Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1021765.1
Update Date:2011-03-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1021765.1 :   SL8500 - Rail Power Strips to Thick to Install  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
275251


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek SL8500 Modular Library System
All Platforms
Checked for relevance on 15-Mar-2011.

Goal

Rail power strips to thick to install in library.
There have been received reports from the field of problems associated with installing rail power strips.

Solution

Steps to Follow
Use the following instructions to order replacement power strips:
Open up a Child SR via MOS to TAPE-HW.  Reference this solution in the case when asking for assistance.

The fix is to order power strips. 
Part Numbers:
-0EF - 313924002  
-1EF - 313924102  
-2EF - 313924202  
-3EF - 313924302  
-4EF - 314826201  
-5EF - 314826301  
 
Required reference information to follow up:

- Customer name
- Size of the library; 5 SEM etc...
- Vendor information on the strips, example:
>  3139243-02 E
>  142214
>  2102 AMPHENOL
>  0923
- Ship to address and contact name
- Pallet serial number


Cause was due to a changed in vendors recently. Engineering has identified the problem; purge underway. The fix is to order power strips; contact Phil Garcia.

SL8500, Rail power strip, Install, Part number, Power strip too thick

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.