Solution  1021042.1 :   L700/L180/L1400 - Drive Diagnosis and Replacement Information  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L700e Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
269768


Applies to:

Sun StorageTek L1400 Tape Library
Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L700e Tape Library
All Platforms
Checked for relevance on 18-Jan-2011.

Goal

L700/L180/L1400 - Drive Diagnosis and Replacement Information
You can use "Drive Status" menu from operator panel (see "Drive Status" on page2-53, L700/1400 Service Manual, PN95846) to check drive's status.

Solution

Typically, drive failures are reported in this menu as:
-Not connected
-Unknown drive
-Not communicating
-Not functional
-Not loadable

Symptom Explanation Conditions That Could Cause This Issue
Client System:
-Cannot access a drive
-Marks drive unavailable
-Detects an unrecoverable error in drive
-Drive has lost power
-Poor or missing SCSI/fiber bus connection
-Defective SCSI/fiber cable
-Damaged tape
-Faulty drive

Steps to Follow
Take the following steps to diagnose these issues:

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :  Customer must place drive offline.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Have customer place the drive offline.

2. Open right side door.

3. At operator panel, consult drive's status (see Table 2-9 on page 2-53). (L700/1400 Service Manual, PN95846)

Does panel display:
-"Not communicating?"
-"Not functional?"
Yes: Go to step 4.  No: Go to step 6.

4. Is drive firmly seated into connector? Yes: Go to step 5.
No: Firmly seat drive into connector.  Go to step 5.

5. Is drive AC switch in on (|) position? Yes: Go to step 6.
No: Set switch on. If drive still fails to function, go to step 10.

6. At operator panel, consult drive's status (see Table 2-9 on page 2-53). (L700/1400 Service Manual, PN95846)
Does panel display "Unknown drive?"
Yes: Check drive type to be sure it matches system requirements. This can be checked in "Lib Config Menu" and "Lib SCSI I/F Config Menu" on operator panel.
No: Go to step 7.

7. At the operator panel, consult drive's status (see Table 2-9 on page 2-53). (L700/1400 Service Manual, PN95846)

Does panel display "Not connected?"
Yes: Drive's Tape Transport Interface (TTI) connector is not firmly connected or AC switch may be off. See steps 4 and 5.
No: Go to step 9.

8. Check host-to-drive cable connection at library bulkhead (SCSI) or fiber component & at drive.
Is cable the correct type & is connection good?
The correct lengths & types of connectors are discussed in Table 1-3 on page 1-6. (L700/1400 Service Manual, PN95846)
Yes: Go to step 10.
No: If cable is:
-Incorrect type---schedule time to replace cable.
-Incorrectly connected or connector is damaged---schedule time to replace cable.

9. If possible, obtain tape that was mounted on drive at time of error.
Have operator make another drive offline and use a system diagnostic test with this tape on that drive.
Was an error encountered? Yes: Go to step 10. 
No: If the cable is incorrect type or incorrectly connected or connector is damaged - schedule time to replace cable.
Yes: Have the operator remove the tape from the system pool.
No: Go to step 10.

10. Drive replacement:

CAUTION:
System interruption: To avoid a system interruption, be sure to carefully follow the step below when replacing the drive.
a. Place the replacement drive in a convenient position near the defective drive's position.
b. Have the operator quiesce the system's SCSI/fiber bus to the drive and make the drive unavailable to the system.
c. Replace the drive:
1. For DLT drives, follow the procedure in "DLT 4000/7000E/8000 Tape Drive" on page 5-67 to replace the drive. (L700/1400 Service Manual, PN95846)
2. For Ultrium drives, follow the procedures in Chapter5 for the specific drive manufacturer.


CAUTION:
Special information for T9x40 and T10000 drives: Consult the T9x40 Tape Drive Service Reference Manual or T10000 tape Drive Service Manual for drive configuration options. The library automatically assigns the same address to the replacement drive. However, you may need to configure other information for the drive before performing the swap.

3. For T9x40 drives, follow the directions in the T9x40 Tape Drive Service Reference Manual to replace the drive.
4. For T10000 drives, follow the directions in the T10000 Tape Drive Service Manual to replace the drive.

11. Recovery information:
Drive, library, and system recovery from the hot swap procedure is explained below.
Once the drive is replaced:
-SCSI "Bus Reset" command is not asserted during the operation
-Library senses that new drive is installed
-Library communications with drive is automatically resumed
-SCSI ID of drive is automatically assigned same ID of drive that was replaced---no reconfiguration or library re-boot is required.
-Drive type, SN & FW version is automatically updated.
-Drive handle is cycled (DLT only)
-Drive is automatically available to library.
-Some system intervention may still be required to make drive available 



Product
Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L1400 Tape Library
StorageTek L700e Tape Library

Drive diagnosis, Replacement, LTO, SDLT, 9840, 9940