Goal

Library Module Type Information as see in 'lib getconfig'.

Solution

The module types are listed in the "Interface Reference Guide" for the SL500
PN96122 Revision: F Chapter 6 SCSI Commands

http://docs.sfbay.sun.com:81/96122F/96122F.pdf
document page 165, pdf page 193

The complete list of Module Type Field Definitions  goes from 0 to 42.

Example:
SERVICE>> lib getconfig
Library Configuration
  Unit Type                      SL500
  Total number of modules        3
    Module 1 type                25          25 = BASE module with drives in the back
    Module 2 type                17          17  = An 8U module (with CAP) with drives in the back
    Module 3 type                16          16 =  The last installed  8U module (with CAP) with drives in the back