Solution Type Technical Instruction Sure Solution 1020235.1 : Netra[TM] CP3140 has less than required MAC addresses for FASTPATH Switching Firmware.
PreviouslyPublishedAs 254668 Description Two CP3140 switches connected to the same router may cause network connectivity failures such as 'ping'. Purpose/Scope: This document shows how to verify if CP3140 is having sufficient MAC Address for its operation. The procedure of replacing CP3140 is covered by standard documentation which can be found at http://www.docs.sun.com Symptoms: If both CP3140 switch boards from the same ct900 platform are connected to a common switch or router, a network connectivity failure such as 'ping' may occur. Internal Bug ID: 6733477 provides additional detail on this issue, and the present work-around is to replace the Netra[TM] CP3140 (PN 375-3282) with a newer version (PN 375-3507). The FASTPATH software uses all 8 available mac addresses from both cards (4 from each card), but it has been noted that earlier versions of the CP3140 card provide only 2 different mac addresses; and thus there are MAC conflicts between the Base Fabric and the Extended Fabric networks. If the Base Fabric network and the Extended Fabric network are connected to each other either directly or through a L2 switch, there will be a MAC conflict between the Extended Fabric network's in-band management MAC address and the Base Fabric network's protocol MAC address. This conflict will cause undeterministic switching behavior when attempting to address the Extended Fabric network's in-band management. Additionally, this can be identified by either visually inspecting the MAC address labels on the blade or by use of the 'show network' command and observing the difference of the mac addresses of the Base and Fabric network mac addresses. Steps to Follow Example by comparing the MAC addresses of the Base vs Fabric networks: (F
stands for "Extended Fabric" and B stands for "Base
Fabric") Product Sun Netra CP3140 ATCA Switch Blade Netra CP3020 Board Netra CP3010 Board Sun Netra CT 900 Server Sun Netra CP3220 ATCA Blade Server Sun Netra CP3260 ATCA Blade Server Sun Netra CP3060 ATCA Blade Server Sun Netra CP3240 Switch Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below: Domain Normalized, Netra, CT900, cable, serial, cabling, ATCA, CP3010, CP3020, CP3060, CP3140, CP3240, CP3220, CP3250, CP3260 Attachments This solution has no attachment |
||||||||||||
|