DescriptionThis document intends to show how to relate a DIMM location as presented in an error message, to the actual physical location on the system board, so that the correct DIMM can be replaced.
Steps to Follow T5140 and T5240 DIMM Decode and Location Info
---------------------------------------------
The T5140/5240 servers can have up to 16 fb-dimms located on the system board,and another
16 possible fb-dimms located on a memory riser card.The memory riser card snaps
onto the system board over the fb-dimms.The fb-dimms are referred to by a "fru name" by
the operating system and service processor.They are identified on the system board and
memory riser board by a "J" location.This document will illustrate how to relate
the "fru name" to the "J" location so the correct fb-dimm can be replaced.
failures of fb-dimms can be displayed by the following commands:
1.) From ILOM
-> show faulty
2.) From ALOM CMT
sc> showfaults -v
3.) From Solaris
fmadm faulty
Decode of Fru Names For Systems Without Memory Riser
----------------------------------------------------
/SYS/MB/CMPX/BRX/CHX/DX
SYSTEM (WILL ALWAYS BE "SYS")_________| | | | | |________DIMM (WILL BE 0 OR 1)
Motherboard (WILL ALWAYS BE "MB")__| | | |___________CHANNEL (WILL ALWAYS BE 0 OR 1)
CPU (WILL BE 0 OR 1) ______| |________________BRANCH (WILL ALWAYS BE 0 OR 1)
FRU Name Location On Motherboard
-------- -----------------------
/SYS/MB/CMP0/BR0/CH0/D0 J0500
/SYS/MB/CMP0/BR0/CH0/D1 J0600
/SYS/MB/CMP0/BR0/CH1/D0 J0700
/SYS/MB/CMP0/BR0/CH1/D1 J0800
/SYS/MB/CMP0/BR1/CH0/D0 J0900
/SYS/MB/CMP0/BR1/CH0/D1 J1000
/SYS/MB/CMP0/BR1/CH1/D0 J1100
/SYS/MB/CMP0/BR1/CH1/D1 J1200
/SYS/MB/CMP1/BR0/CH0/D0 J1800
/SYS/MB/CMP1/BR0/CH0/D1 J1900
/SYS/MB/CMP1/BR0/CH1/D0 J2000
/SYS/MB/CMP1/BR0/CH1/D1 J2100
/SYS/MB/CMP1/BR1/CH0/D0 J2200
/SYS/MB/CMP1/BR1/CH0/D1 J2300
/SYS/MB/CMP1/BR1/CH1/D0 J2400
/SYS/MB/CMP1/BR1/CH1/D1 J2500
Decode of Fru Names For Systems With Memory Riser
-------------------------------------------------
/SYS/MB/CMPX/MRX/BRX/CHX/DX
SYSTEM (WILL ALWAYS BE "SYS")_________| | | | | | |________DIMM (WILL BE 0 1 2 OR 3)
Motherboard (WILL ALWAYS BE "MB")__| | | | |___________CHANNEL (WILL ALWAYS BE 0 OR 1)
CPU (WILL BE 0 OR 1)______| | |________________BRANCH (WILL ALWAYS BE 0 OR 1)
MEMORY RISER (WILL BE 0 OR 1) ____________|
FRU Name Location On Motherboard
-------- -----------------------
/SYS/MB/CMP0/BR0/CH0/D0 J0500
/SYS/MB/CMP0/BR0/CH0/D1 J0600
/SYS/MB/CMP0/BR0/CH1/D0 J0700
/SYS/MB/CMP0/BR0/CH1/D1 J0800
/SYS/MB/CMP0/BR1/CH0/D0 J0900
/SYS/MB/CMP0/BR1/CH0/D1 J1000
/SYS/MB/CMP0/BR1/CH1/D0 J1100
/SYS/MB/CMP0/BR1/CH1/D1 J1200
/SYS/MB/CMP1/BR0/CH0/D0 J1800
/SYS/MB/CMP1/BR0/CH0/D1 J1900
/SYS/MB/CMP1/BR0/CH1/D0 J2000
/SYS/MB/CMP1/BR0/CH1/D1 J2100
/SYS/MB/CMP1/BR1/CH0/D0 J2200
/SYS/MB/CMP1/BR1/CH0/D1 J2300
/SYS/MB/CMP1/BR1/CH1/D0 J2400
/SYS/MB/CMP1/BR1/CH1/D1 J2500
Location on Memory Riser 0
--------------------------
/SYS/MB/CMP0/MR0/BR0/CH0/D2 J0201
/SYS/MB/CMP0/MR0/BR0/CH0/D3 J0301
/SYS/MB/CMP0/MR0/BR0/CH1/D2 J0401
/SYS/MB/CMP0/MR0/BR0/CH1/D3 J0501
/SYS/MB/CMP0/MR0/BR1/CH0/D2 J0601
/SYS/MB/CMP0/MR0/BR1/CH0/D3 J0701
/SYS/MB/CMP0/MR0/BR1/CH1/D2 J0801
/SYS/MB/CMP0/MR0/BR1/CH1/D3 J0901
Location on Memory Riser 1
--------------------------
/SYS/MB/CMP1/MR1/BR0/CH0/D2 J0201
/SYS/MB/CMP1/MR1/BR0/CH0/D3 J0301
/SYS/MB/CMP1/MR1/BR0/CH1/D2 J0401
/SYS/MB/CMP1/MR1/BR0/CH1/D3 J0501
/SYS/MB/CMP1/MR1/BR1/CH0/D2 J0601
/SYS/MB/CMP1/MR1/BR1/CH0/D3 J0701
/SYS/MB/CMP1/MR1/BR1/CH1/D2 J0801
/SYS/MB/CMP1/MR1/BR1/CH1/D3 J0901
T5140/5240 System Board
___________________________________________________________________________
| /SYS/MB/CMP1 front of system /SYS/MB/CMP0 |
| _______________ _______________ |
| | | | | |
| | | | | |
| | CPU | | CPU | |
| | CMP 1 | | CMP 0 | |
| |
Products
Sun SPARC Enterprise T5140 Server
Sun SPARC Enterprise T5240 Server
Internal Comments
See Also:
Sun SPARC Enterprise(R) T5140:
FB-DIMM Configuration Guidelines
Sun SPARC Enterprise(R) T5240:
FB-DIMM Configuration Guidelines
T5140, T5240, maramba, DIMM
Change History
Date: 2011-01-11
User name: Dencho Kojucharov
Action: Currency check
Comments: audited by Entry-Level SPARC Content Lead
updated broken reference links in internal section
Attachments
This solution has no attachment