Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1020018.1
Update Date:2011-04-11
Keywords:

Solution Type  Technical Instruction Sure

Solution  1020018.1 :   Confirm network settings are correct  


Related Items
  • Sun Fire T2000 Server
  •  
  • Sun Fire T1000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Operating Systems>Solaris Network
  •  
  • GCS>Sun Microsystems>Servers>CMT Servers
  •  

PreviouslyPublishedAs
250928


Description
This document would explain the details of required steps to confirm network settings are correct

Steps to Follow
We will provide an overview of confirming correct network settings in LDOM
***NOTE*** Configuration changes to LDoms need to be saved to the SP using the
ldm(1M) add-config subcommand. If not, the configurations will be lost when the
primary domain is rebooted.


We are using one control domain and two guest domains in the below configuration
# /opt/SUNWldm/bin/ldm ls
NAME             STATE      FLAGS   CONS    VCPU  MEMORY   UTIL  UPTIME
primary          active            -n-cv-       SP             8         896M         0.2%   10d 20h 24m
ldom01           active           -n----      5000           8            1G           0.0%   2d 14h 49m
ldom02           active           -n----      5001           8             1G          0.0%   1d 14h 40m


#  /opt/SUNWldm/bin/ldm list-domain -o network primary
NAME
primary

MAC
    00:21:28:16:d8:5c

VSW
    NAME             MAC                       NET-DEV   DEVICE     DEFAULT-VLAN-ID PVID VID                  MODE
    primary-vsw0     00:21:28:16:d8:5c     e1000g0   switch@0            1                             1  
    primary-vsw1     00:14:4f:c9:e3:ba       nxge0       switch@1            1                             1  

#  /opt/SUNWldm/bin/ldm list-domain -o network ldom01
NAME
ldom01

MAC
    00:14:4f:fa:33:e5

NETWORK
    NAME             SERVICE                          DEVICE             MAC               MODE   PVID VID
    vnet0            primary-vsw0@primary        network@0     00:14:4f:f8:e2:d9                      1
    vnet1            primary-vsw1@primary        network@1     00:14:4f:f8:c9:7e      hybrid       1

#  /opt/SUNWldm/bin/ldm list-domain -o network ldom02
NAME
ldom02

MAC
    00:14:4f:fd:51:ea

NETWORK
    NAME             SERVICE                     DEVICE                  MAC                       MODE   PVID VID
    vnet0            primary-vsw0@primary        network@0     00:14:4f:b2:e1:d1                           1
    vnet1            primary-vsw1@primary        network@1     00:14:4f:b8:b3:7a             hybrid     1

Control domain IP address:
# ifconfig -a
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
        inet 127.0.0.1 netmask ff000000
vsw0: flags=201000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4,CoS> mtu 1500 index 2
        inet 10.5.60.232 netmask fffff800 broadcast 10.5.63.255
        ether 0:21:28:16:d8:5c


Guest domain ldom01 IP address:
# ifconfig -a
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
        inet 127.0.0.1 netmask ff000000
vnet0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
        inet 10.5.63.112 netmask fffff800 broadcast 10.5.63.255
        ether 0:14:4f:f8:e2:d9
vnet1: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 3
        inet 192.1.1.3 netmask ffffff00 broadcast 192.1.1.255
        ether 0:14:4f:f8:c9:7e


Guest domain ldom02 IP address:
# ifconfig -a
lo0: flags=2001000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4,VIRTUAL> mtu 8232 index 1
        inet 127.0.0.1 netmask ff000000
vnet0: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 2
        inet 10.5.63.113 netmask fffff800 broadcast 10.5.63.255
        ether 0:14:4f:b2:e1:d1
vnet1: flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv4> mtu 1500 index 3
        inet 192.1.1.4 netmask ffffff00 broadcast 192.1.1.255
        ether 0:14:4f:b8:b3:7a

  1.  ping test ( non hybrid )
      a) from guest domain to control domain/primary domain
         ldom01> ping 10.5.60.232
                 10.5.58.211 is alive
        
      b) from one guest domain(ldom01) to another guest domain(ldom02) which are on the same subnet
         ldom01> ping 10.5.63.113
                 10.5.63.113 is alive

      c) from guest domain to external machine IP address
         ldom01># ping  10.5.58.211
         & Sun Fire T2000 Server
    Sun Fire T1000 Server


    Internal Comments
    This document contains normalized content and is managed by the the Domain Lead
    (s) of the respective domains. To notify content owners of a knowledge gap
    contained in this document, and/or prior to updating this document, please
    contact the domain engineers that are managing this document via the "Document
    Feedback" alias(es) listed below:

    Normalization Lead: [email protected]

    Normalized, ldom, ldm, guest , domain, network, issues, vnet, vsw, vswitch, virtual network interface, hyrbrid I/O, DHCP

    Attachments
    This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.