Description
This documents describes how to recover Sun[TM] Switch Blade (Netra[TM] CP3140/CP3240) Configuration if it is lost or cleared by “clear config” command.
Symptoms
  • CP3140/CP3240 is not working as expected

  • CP3140/CP3240 configuration has been cleared by “clear config” command

  • CP3140/CP3240 configuration issue

Purpose and Scope

This document gives details on how to recover CP3140/CP3240 configuration Netra CT900.



Steps to Follow
Items needed to recover CP3140/CP3240 configuration if not existed already:

1. Configure CP3140/CP3240 “serviceport” or “network”
2. Connect the NET MGT (Network Management) port to the intranet
3. A working tftp/ftp server that is reachable by the above intranet
4. A fully configured and working expected CP3140/CP3240
  • Configure CP3140/CP3240 “serviceport” or “network”

Please refer to the "Netra[TM] CT900 Server switch Software Reference Manual" (PN: 819-3774) and "Netra[TM] CP3240 Software Reference Manual" (PN: 820-3253) for the details on how to set up the “serviceport” or “network.”

  • Connect the NET MGT (Network Management) port to the intranet

Connect the NET MGT port on the front panel to the lab/building network. The tftp/ftp service only goes through this particular port.


Steps needed to recover CP3140/CP3240 configuration:

  1. Back up a binary configuration file form a working (source) CP3140/3240

  2. Copy the binary configuration to the problematic (target) CP3140/CP3240


  • Back up a binary configuration file form a working (source) CP3140/3240

Log into the working CP3140/CP3240 that to backup the configuration file from, and enter Privileged Exec Mode:

User:admin
Password:

NOTE: Enter '?' for Command Help. Command help displays all options
that are valid for the 'normal' and 'no' command forms. For
the syntax of a particular command form, please consult the
documentation.

(ATS1160 Base) >enable
Password:

(ATS1160 Base) #

Use “show serviceport” or “show network” to make sure it is configured, and ping the tftp server to make sure it is reachable:

(ATS1160 Base) #show serviceport

IP Address..................................... 10.5.63.120
Subnet Mask.................................... 255.255.248.0
Default Gateway................................ 10.5.56.1
ServPort Configured Protocol Current........... None
Burned In MAC Address.......................... 00:20:13:F0:BE:3C

(ATS1160 Base) #ping 10.5.58.95

Send count=3, Receive count=3 from 10.5.58.95

(ATS1160 Base) #

Use the “copy” command to backup the current running configuration, and save it to a tftp server. First, need to copy the running configuration to a NVRAM:

(ATS1160 Base) #copy system:running-config nvram:startup-config

This operation may take a few minutes.
Management interfaces will not be available during this time.

Are you sure you want to save? (y/n) y

Configuration Saved!

(ATS1160 Base) #

Then move the NVRAM content to a tftp server:

(ATS1160 Base) #copy nvram:startup-config tftp://10.5.58.95/cp3140-base.cfg

Mode........................................... TFTP
Set TFTP Server IP............................. 10.5.58.95
TFTP Path...................................... ./
TFTP Filename.................................. cp3140-base.cfg
Data Type...................................... Config File

Are you sure you want to start? (y/n) y
TFTP Config transfer starting...

File transferation completed successfully.

(ATS1160 Base) #


In the above example, 10.5.58.95 is the IP Address of a tftp server, and the file name can be any name given by the user.
  • Copy the binary configuration to the problematic (target) CP3140/CP3240

Copy the backup configuration from the tftp server to the problematic CP3140/CP3240:

(ATS1160 Base) #copy tftp://10.5.58.95/cp3140-base-sun-r2.0.1.cfg system:running-config

Mode........................................... TFTP
Set TFTP Server IP............................. 10.5.58.95
TFTP Path...................................... ./
TFTP Filename.................................. cp3140-base.cfg
Data Type...................................... Config

Download configuration file. Current configuration will be cleared.
Are you sure you want to start? (y/n) y

Configuration update completed successfully.

(ATS1160 Base) #
(Unit 1)>
User:


References:

http://docs.sun.com/app/docs/coll/netra-ct900



Product
Netra CT 900 Server
Netra CP3010 Board
Netra CP3240 Switch
Sun Netra CP3020 ATCA Blade Server
Sun Netra CP3060 ATCA Blade Server
Sun Netra CP3140 ATCA Switch Blade
Sun Netra CP3220 ATCA Blade Server
Sun Netra CP3260 ATCA Blade Server

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]





normalized, CT900, Netra, ATCA, shelf, clia, summary, pigeon point, CP3010, CP3020, CP3060, CP3220, CP3250, CP3260, CP3140, CP3240, ShMM, ShMc

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback