Solution Type Technical Instruction Sure Solution 1019730.1 : Sun SPARC(R) Enterprise M3000 Server Device Paths
PreviouslyPublishedAs 244806 Description The intent of this document is to provide the reader with an overview of how the Sun SPARC Enterprise(R) M3000 system device paths are arranged. Steps to Follow - NEW The following is a graphical representation of the Sun SPARC Enterprise M3000 device path layout: |----- /pci@0,600000/pci@0 (Base Path) |-- ../pci@0/scsi@0/disk0 HD0 |-- ../pci@0/scsi@0/disk1 HD1 |-- ../pci@0/scsi@0/disk2 HD2 |-- ../pci@0/scsi@0/disk3 HD3 |-- ../pci@0/scsi@0/disk4 DVD |-- ../pci@0/scsi@0/disk5 or 6 SAS port |-- ..pci@1/pci@0/network@4 BGE0 |-- ..pci@1/pci@0/network@4,1 BGE1 |-- ..pci@2/pci@0/network@4 BGE2 |-- ..pci@2/pci@0/network@4,1 BGE3 |-- ..pci@8 Slot 0 (PCIe) |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe) |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe) |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)
For more information on Sun SPARC Enterprise M8000/M9000
device paths, see Technical Instruction < Solution: 205724 > Sun SPARC Enterprise M8000 and M9000 Device Paths. For more information on Sun SPARC Enterprise M4000/M5000 device paths, see Technical Instruction < Solution: 203831 > Sun SPARC Enterprise M4000 and M5000 Device Paths. For more information on External I/O Expansion Unit device
paths, see Technical Instruction < Solution: 207442 > Sun SPARC External I/O Expansion Unit Device Paths. Actual device paths may be seen using some of the following methods: OBP: show-devs command Solaris: /etc/path_to_inst file Solaris: prtpicl command Solaris: prtdiag -v command Internal CommentsThis document contains normalized content and is managed by the the Domain Engineer(s) of the respective domains. This document references external documents which are also available internally as: Technical Instruction - < Document 1011446.1 > -Enterprise Mx000 Servers Logical System Board (LSB) Technical Instruction - < Document 1004116.1 > -Sun SPARC Enterprise M8000 and M9000 Device Paths Technical Instruction - < Document 1002807.1 > -Sun SPARC Enterprise M4000 and M5000 Device Paths Technical Instrustion - < Document 1005332.1 > -Sun SPARC External I/O Expansion Unit Device Paths. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the Document Feedback alias(es) listed below:
Date: 2010-05-04 User: Cootware Action: Tech Review changes Comment: Link is corrected. Content is valid M3000, OPL, Device Paths, Normalized Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|