Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1019723.1 : VTL - How to replace physical tape drive on backend of VTL server
PreviouslyPublishedAs 244627 This procedure to replace physical tape drive on backend of VTL system can be used by Oracle field or if drive is a CRU, can be done by customer.
Applies to:Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 [Release: 1.0 to 2.0]Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 and later [Release: 4.0 and later] All Platforms GoalSteps to take when replacing a physical tape drive on the backend of a VTL system.SolutionSteps to Follow1. Record 'device id' of current drive (in VTL Console GUI, under VirtualTape Library System>Physical Tape Libraries, highlight drive and 'device id' will be in right panel) 2. Unassign physical drive from VTL (in VTL Console GUI, under VirtualTape Library System>Physical Tape Libraries, right click on drive to be removed and select 'Unassign') 3. Remove/replace physical drive in physical library 4. If using ACSLS, configure the new drive: config drive 'panel_id' (for example, if VTL has device id as 0,2, 1,12, enter 'config drive 0,2,1') 5. Assign new drive to VTL (in VTL Console GUI, under VirtualTape Library System>Physical Tape Libraries, right click physical library name, select 'Assign', and add device id recorded in step 1). 6. Perform a test migrate/export to validate new configuration. Refer to VTL User's Guide or ACSLS ICAG for details on any step above (see Reference section below for links). Referenceshttp://docs.sfbay.sun.com/app/docs/prod/tape.virtual#hichttp://www.oracle.com/technetwork/documentation/tape-storage-187555.html Attachments This solution has no attachment |
||||||||||||
|