Description
This document is intended as a reference document when needing to translate between command and status addresses and physical components within the Netra CT900

Symptoms:

  • Need to identify the hardware addresses of CT900 FRUs

Purpose/Scope:

Different commands within the Netra CT900 use different references and address formats. This document is intended to bring the physical and logical references into one mapping table



Steps to Follow
Use the table below to identify which hardware address or IPMI bus address to use when using commands that require an address, or when interpreting status output.

The Power Zone column is added for convenience when needing to recognise which power input is feeding which physical board.
IPMB = Intelligent Platform Management Bus

Physical
Slot

Logical Slot

Function

Hardware Address

IPMB Address

Power Zone

1

13

Node Board

0x4D

0x9A

1

2

11

Node Board

0x4B

0x96

2

3

9

Node Board

0x49

0x92

1

4

7

Node Board

0x47

0x8E

2

5

5

Node Board

0x45

0x8A

1

6

3

Node Board

0x43

0x86

2

7

1

Switch Board

0x41

0x82

2

8

2

Switch Board

0x42

0x84

3

9

4

Node Board

0x44

0x88

3

10

6

Node Board

0x46

0x8C

4

11

8

Node Board

0x48

0x90

3

12

10

Node Board

0x4A

0x94

4

13

12

Node Board

0x4C

0x98

3

14

14

Node Board

0x4E

0x9C

4

Upper ShMM

n/a

Shelf Manager Module

0x08

0x10

2

Lower ShMM

n/a

Shelf Manager Module

0x09

0x12

3

Fan 1

n/a

Fan Module

0x10*

0x20

1

Fan 2

n/a

Fan Module

0x10*

0x20

2

Fan 3

n/a

Fan Module

0x10*

0x20

3

SAP

n/a

Shelf Alarm Panel

0x10*

0x20

3



* All the node boards and the shelf managers have Intelligent Platform Management Interface Controller (IPMC) chips which communicate across the IPMB. However, there is no IPMC on the other parts. The environmental status and control for these parts are communicated across a basic I2C bus and so have a common hardware address of 0x10.

To verify the hardware address list you can use the clia shelf at (address translation) command from the active ShMM

Example:

# clia shelf at

Pigeon Point Shelf Manager Command Line Interpreter
PICMG Address Table Record (ID=0x10)
    Version = 0
Shelf Address = 1
Address Table Entries# = 25
    Hw Addr: 41, Site # 7, Type: "AdvancedTCA Board" 00
    Hw Addr: 42, Site # 8, Type: "AdvancedTCA Board" 00
    Hw Addr: 43, Site # 6, Type: "AdvancedTCA Board" 00
    Hw Addr: 44, Site # 9, Type: "AdvancedTCA Board" 00
    Hw Addr: 45, Site # 5, Type: "AdvancedTCA Board" 00
    Hw Addr: 46, Site # 10, Type: "AdvancedTCA Board" 00
    Hw Addr: 47, Site # 4, Type: "AdvancedTCA Board" 00
    Hw Addr: 48, Site # 11, Type: "AdvancedTCA Board" 00
    Hw Addr: 49, Site # 3, Type: "AdvancedTCA Board" 00
    Hw Addr: 4a, Site # 12, Type: "AdvancedTCA Board" 00
    Hw Addr: 4b, Site # 2, Type: "AdvancedTCA Board" 00
    Hw Addr: 4c, Site # 13, Type: "AdvancedTCA Board" 00
    Hw Addr: 4d, Site # 1, Type: "AdvancedTCA Board" 00
    Hw Addr: 4e, Site # 14, Type: "AdvancedTCA Board" 00
    Hw Addr: 08, Site # 1, Type: "Dedicated ShMC" 03
    Hw Addr: 09, Site # 2, Type: "Dedicated ShMC" 03
    Hw Addr: 10, Site # 1, Type: "OEM" c0
    Hw Addr: 10, Site # 1, Type: "Shelf FRU Information" 02
    Hw Addr: 10, Site # 2, Type: "Shelf FRU Information" 02
    Hw Addr: 10, Site # 1, Type: "Fan Tray" 04
    Hw Addr: 10, Site # 2, Type: "Fan Tray" 04
    Hw Addr: 10, Site # 3, Type: "Fan Tray" 04
    Hw Addr: 10, Site # 1, Type: "Power Entry" 01
    Hw Addr: 10, Site # 2, Type: "Power Entry" 01
    Hw Addr: 10, Site # 1, Type: "Alarm" 06
#





Product
Sun Netra CT 900 Server
Netra CP3010 Board
Netra CP3020 Board
Netra CP3060 Board
Sun Netra CP3220 ATCA Blade Server
Sun Netra CP3260 ATCA Blade Server
Netra CP3240 Switch
Sun Netra CP3140 ATCA Switch Blade



Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]

normalized, ATCA, CT900, CP3010, CP3020, CP3060, CP3220, CP3250, CP3260, CP3140, CP3240, translation, map

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback