Asset ID: |
1-71-1019506.1 |
Update Date: | 2009-08-18 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1019506.1
:
How to map physical locations and functions to logical addresses on the Sun Netra CT900
Related Items |
- Sun Netra CT900 Server
- Sun Netra CP3260 ATCA Blade Server
- Sun Netra CP3220 ATCA Blade Server
- Sun Netra CP3010 Blade Server
|
Related Categories |
- GCS>Sun Microsystems>Boards>NEBS-Certified Servers
- GCS>Sun Microsystems>Servers>NEBS-Certified Servers
|
PreviouslyPublishedAs
240285
DescriptionThis document is intended as a reference document when needing to translate between command and status addresses and physical components within the Netra CT900
Symptoms:
Purpose/Scope:
Different commands
within the Netra CT900 use different references and address formats.
This document is intended to bring the physical and logical
references into one mapping table
Steps to FollowUse the table below to identify which hardware address or IPMI bus address to use when using commands that require an address, or when interpreting status output.
The
Power Zone column is added for convenience when needing to recognise
which power input is feeding which physical board.
IPMB =
Intelligent Platform Management Bus
-
Physical Slot
|
Logical
Slot
|
Function
|
Hardware
Address
|
IPMB
Address
|
Power
Zone
|
1
|
13
|
Node
Board
|
0x4D
|
0x9A
|
1
|
2
|
11
|
Node
Board
|
0x4B
|
0x96
|
2
|
3
|
9
|
Node
Board
|
0x49
|
0x92
|
1
|
4
|
7
|
Node
Board
|
0x47
|
0x8E
|
2
|
5
|
5
|
Node
Board
|
0x45
|
0x8A
|
1
|
6
|
3
|
Node
Board
|
0x43
|
0x86
|
2
|
7
|
1
|
Switch
Board
|
0x41
|
0x82
|
2
|
8
|
2
|
Switch
Board
|
0x42
|
0x84
|
3
|
9
|
4
|
Node
Board
|
0x44
|
0x88
|
3
|
10
|
6
|
Node
Board
|
0x46
|
0x8C
|
4
|
11
|
8
|
Node
Board
|
0x48
|
0x90
|
3
|
12
|
10
|
Node
Board
|
0x4A
|
0x94
|
4
|
13
|
12
|
Node
Board
|
0x4C
|
0x98
|
3
|
14
|
14
|
Node
Board
|
0x4E
|
0x9C
|
4
|
Upper
ShMM
|
n/a
|
Shelf
Manager Module
|
0x08
|
0x10
|
2
|
Lower
ShMM
|
n/a
|
Shelf
Manager Module
|
0x09
|
0x12
|
3
|
Fan
1
|
n/a
|
Fan
Module
|
0x10*
|
0x20
|
1
|
Fan
2
|
n/a
|
Fan
Module
|
0x10*
|
0x20
|
2
|
Fan
3
|
n/a
|
Fan
Module
|
0x10*
|
0x20
|
3
|
SAP
|
n/a
|
Shelf
Alarm Panel
|
0x10*
|
0x20
|
3
|
* All the node
boards and the shelf managers have Intelligent Platform Management
Interface Controller (IPMC) chips which communicate across the IPMB.
However, there is no IPMC on the other parts. The environmental
status and control for these parts are communicated across a basic
I2C bus and so have a common hardware address of 0x10.
To
verify the hardware address list you can use the clia shelf at
(address translation) command from the active ShMM
Example:
#
clia shelf at
Pigeon Point Shelf Manager Command Line
Interpreter
PICMG Address Table Record (ID=0x10)
Version
= 0
Shelf Address = 1
Address Table Entries# = 25
Hw
Addr: 41, Site # 7, Type: "AdvancedTCA Board" 00
Hw
Addr: 42, Site # 8, Type: "AdvancedTCA Board" 00
Hw
Addr: 43, Site # 6, Type: "AdvancedTCA Board" 00
Hw
Addr: 44, Site # 9, Type: "AdvancedTCA Board" 00
Hw
Addr: 45, Site # 5, Type: "AdvancedTCA Board" 00
Hw
Addr: 46, Site # 10, Type: "AdvancedTCA Board" 00
Hw
Addr: 47, Site # 4, Type: "AdvancedTCA Board" 00
Hw
Addr: 48, Site # 11, Type: "AdvancedTCA Board" 00
Hw
Addr: 49, Site # 3, Type: "AdvancedTCA Board" 00
Hw
Addr: 4a, Site # 12, Type: "AdvancedTCA Board" 00
Hw
Addr: 4b, Site # 2, Type: "AdvancedTCA Board" 00
Hw
Addr: 4c, Site # 13, Type: "AdvancedTCA Board" 00
Hw
Addr: 4d, Site # 1, Type: "AdvancedTCA Board" 00
Hw
Addr: 4e, Site # 14, Type: "AdvancedTCA Board" 00
Hw
Addr: 08, Site # 1, Type: "Dedicated ShMC" 03
Hw
Addr: 09, Site # 2, Type: "Dedicated ShMC" 03
Hw
Addr: 10, Site # 1, Type: "OEM" c0
Hw
Addr: 10, Site # 1, Type: "Shelf FRU Information" 02
Hw
Addr: 10, Site # 2, Type: "Shelf FRU Information" 02
Hw
Addr: 10, Site # 1, Type: "Fan Tray" 04
Hw
Addr: 10, Site # 2, Type: "Fan Tray" 04
Hw
Addr: 10, Site # 3, Type: "Fan Tray" 04
Hw
Addr: 10, Site # 1, Type: "Power Entry" 01
Hw
Addr: 10, Site # 2, Type: "Power Entry" 01
Hw
Addr: 10, Site # 1, Type: "Alarm" 06
#
ProductSun Netra CT 900 Server
Netra CP3010 Board
Netra CP3020 Board
Netra CP3060 Board
Sun Netra CP3220 ATCA Blade Server
Sun Netra CP3260 ATCA Blade Server
Netra CP3240 Switch
Sun Netra CP3140 ATCA Switch Blade
Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the "Document Feedback" alias(es) listed below:
Domain Lead:
[email protected]
Feedback Alias:
[email protected]
normalized, ATCA, CT900, CP3010, CP3020, CP3060, CP3220, CP3250, CP3260, CP3140, CP3240, translation, map
Attachments
This solution has no attachment