Description
This document describes how to verify the incoming power and power distribution
within the Netra[TM] CT 900

Symptoms

  • Shelf dead

  • Chassis dead

  • Blade dead

  • Can't power up Blade


Purpose/Scope

The Netra CT 900 chassis has eight power input feeds split across two redundant Power Entry Modules. Within the Shelf (chassis), these supplies are spread across four zones. This document describes the procedures to check that the power is present and correct at the input to the Sun Netra CT 900 and that the power distribution within the shelf is correctly configured to supply the power required for the boards that are installed.



Steps to Follow
These are the steps to follow
  • Verify the state of the LEDs on each of the boards

The LEDs on each board will help to identify whether the problem is localized to a single board or affects a group of components or even the entire shelf.

See <Document: 1019516.1>

  • Verify the shelf has incoming power

The Netra CT900 has two redundant power entry modules known as PEMs located at the rear of the shelf. These PEMs take -48V DC power inputs and distribute power to the rest of the system. Each of the feeds should be individually protected via circuit breakers. The loss of an individual feed or a complete PEM should not cause the shelf to go down.

If the shelf appears completely dead, i.e. no LEDS illuminated, or no sound of fans turning, verify external power is available and that the circuit breakers are in the on position. Any problems in this area may require the assistance of the site electrician.

  • Verify available shelf power

Early model chassis referred to the Power Entry Modules as PEM-A and PEM-B.

Later models refer to them as PEM-1 and PEM-2. The following table indicates the origin of each feed (numbered 0 through 7) and the zones they support (numbered 1 through 4).

Component

PEM

Terminal (Zone)

Feed

Fan Tray 1

1

2

1

Fan Tray 1

2

2

5

Fan Tray 2

1

3

2

Fan Tray 2

2

3

6

Fan Tray 3

1

4

3

Fan Tray 3

2

4

7

ShMM 1

1

2

1

ShMM 1

2

2

5

ShMM 2

1

3

2

ShMM 2

2

3

6

Slot 1

1

1

0

Slot 1

2

1

4

Slot 2

1

2

1

Slot 2

2

2

5

Slot 3

1

1

0

Slot 3

2

1

4

Slot 4

1

2

1

Slot 4

2

2

5

Slot 5

1

1

0

Slot 5

2

1

4

Slot 6

1

2

1

Slot 6

2

2

5

Slot 7

1

2

1

Slot 7

2

2

5

Slot 8

1

3

2

Slot 8

2

3

6

Slot 9

1

3

2

Slot 9

2

3

6

Slot 10

1

4

3

Slot 10

2

4

7

Slot 11

1

3

2

Slot 11

2

3

6

Slot 12

1

4

3

Slot 12

2

4

7

Slot 13

1

3

2

Slot 13

2

3

6

Slot 14

1

4

3

Slot 14

2

4

7

If zone 2 and or zone 3 power is available, then one or both the shelf managers (ShMM) will power up and allow access to the system for further checks.

Log into the active shelf manager using either the serial management port connection via the alarm card (refer to document <Document: 1019404.1> or through the network (assumes network connected and active). Refer to documents <Document: 1017986.1> and <Document: 1005533.1> verifying external network

  • Confirm you are on the active ShMM

# clia shmstatus

Pigeon Point Shelf Manager Command Line Interpreter

Host: "Active"

#

  • Verify the incoming power feeds are present using the clia shelf power distribution command

Check the value for the parameter "Maximum External Available Current" for feed 00 through to feed 07 is showing 28 amps. If power is missing from an individual feed it will show 0 amps.

This output also shows the FRU address for each of the boards on a particular feed. The "FRU Addr" given in this output is the Hardware Address of the board. To convert to a physical board refer to document <Document: 1019506.1>

Example:

# clia shelf power_distribution



Pigeon Point Shelf Manager Command Line Interpreter



PICMG Shelf Power Distribution Record (ID=0x11)

Version = 0

Feed count: 8

Feed 00:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 343.100 Watts

Feed-to-FRU Mapping entries count: 3

FRU Addr: 45, FRU ID: 0xfe

FRU Addr: 49, FRU ID: 0xfe

FRU Addr: 4d, FRU ID: 0xfe

Feed 01:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 543.100 Watts

Feed-to-FRU Mapping entries count: 6

FRU Addr: 41, FRU ID: 0xfe

FRU Addr: 43, FRU ID: 0xfe

FRU Addr: 47, FRU ID: 0xfe

FRU Addr: 4b, FRU ID: 0xfe

FRU Addr: 08, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x03

Feed 02:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 330.000 Watts

Feed-to-FRU Mapping entries count: 6

FRU Addr: 42, FRU ID: 0xfe

FRU Addr: 44, FRU ID: 0xfe

FRU Addr: 48, FRU ID: 0xfe

FRU Addr: 4c, FRU ID: 0xfe

FRU Addr: 09, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x04

Feed 03:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 230.000 Watts

Feed-to-FRU Mapping entries count: 4

FRU Addr: 46, FRU ID: 0xfe

FRU Addr: 4a, FRU ID: 0xfe

FRU Addr: 4e, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x05

Feed 04:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 343.100 Watts

Feed-to-FRU Mapping entries count: 3

FRU Addr: 45, FRU ID: 0xfe

FRU Addr: 49, FRU ID: 0xfe

FRU Addr: 4d, FRU ID: 0xfe

Feed 05:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 543.100 Watts

Feed-to-FRU Mapping entries count: 6

FRU Addr: 41, FRU ID: 0xfe

FRU Addr: 43, FRU ID: 0xfe

FRU Addr: 47, FRU ID: 0xfe

FRU Addr: 4b, FRU ID: 0xfe

FRU Addr: 08, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x03

Feed 06:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 330.000 Watts

Feed-to-FRU Mapping entries count: 6

FRU Addr: 42, FRU ID: 0xfe

FRU Addr: 44, FRU ID: 0xfe

FRU Addr: 48, FRU ID: 0xfe

FRU Addr: 4c, FRU ID: 0xfe

FRU Addr: 09, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x04

Feed 07:

Maximum External Available Current: 28.0 Amps

Maximum Internal Current: 27.6 Amps

Minimum Expected Operating Voltage: -40.5 Volts

Actual Power Available: 1117.800 Watts

Currently Used Power: 230.000 Watts

Feed-to-FRU Mapping entries count: 4

FRU Addr: 46, FRU ID: 0xfe

FRU Addr: 4a, FRU ID: 0xfe

FRU Addr: 4e, FRU ID: 0xfe

FRU Addr: 10, FRU ID: 0x05



#



  • Check the power requirement matches the power allowance for each slot using the clia shelf -v power_management command

The amount of power allowed by the Shelf manager for the slot is shown by the parameter "Maximum FRU Power Capabilities". Note: These values differ depending on the Chassis/ShMM firmware level.

The amount of power requested by the board and subsequently allocated is shown by the parameter "Currently Assigned Power"

If the board requests more power than is allowed for the slot, the board will not power up

Example:

# clia shelf -v power_management



Pigeon Point Shelf Manager Command Line Interpreter



PICMG Shelf Activation And Power Management Record (ID=0x12)

Version = 1

Allowance for FRU Activation Readiness: 20 seconds

FRU Activation and Power Description Count: 17

Hw Address: 41, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 60.0 Watts



Hw Address: 42, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 60.0 Watts



Hw Address: 43, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 163.1 Watts



Hw Address: 44, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 100.0 Watts



Hw Address: 45, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 163.1 Watts



Hw Address: 46, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 100.0 Watts



Hw Address: 47, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 48, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 49, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 4a, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 4b, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 150.0 Watts



Hw Address: 4c, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 4d, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 150.0 Watts



Hw Address: 4e, FRU ID: 0xfe, Maximum FRU Power Capabilities: 235 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 0.0 Watts



Hw Address: 08, FRU ID: 0xfe, Maximum FRU Power Capabilities: 24 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 20.0 Watts



Hw Address: 09, FRU ID: 0xfe, Maximum FRU Power Capabilities: 24 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 20.0 Watts



Hw Address: 10, FRU ID: 0xfe, Maximum FRU Power Capabilities: 680 Watts

Shelf Manager Controlled Activation: Enabled

Shelf Manager Controlled Deactivation: Enabled

Delay Before Next Power On: 0.0 seconds

Currently Assigned Power: 327.0 Watts





Product
Sun Netra CT 900 Server
Netra CP3010 Board
Netra CP3020 Board
Netra CP3060 Board
Sun Netra CP3220 ATCA Blade Server
Sun Netra CP3250 ATCA Blade Server
Sun Netra CP3260 ATCA Blade Server
Sun Netra CP3140 ATCA Switch Blade
Netra CP3240 Switch

Internal Comments
This document contains normalized content and is managed by the the Domain Lead
(s) of the respective domains. To notify content owners of a knowledge gap
contained in this document, and/or prior to updating this document, please
contact the domain engineers that are managing this document via the "Document
Feedback" alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]

normalized, verify, power, dead, ATCA, Netra, CT900, CP3010, CP3020, CP3060, CP3140, CP3240, CP3220, CP3250, CP3260

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback