Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1019274.1
Update Date:2010-09-15
Keywords:

Solution Type  Technical Instruction Sure

Solution  1019274.1 :   BIOS device scanning order on Galaxy family systems  


Related Items
  • Sun Fire X4200 M2 Server
  •  
  • Sun Fire X4600 Server
  •  
  • Sun Fire X4100 Server
  •  
  • Sun Fire X4100 M2 Server
  •  
  • Sun Fire X4200 Server
  •  
  • Sun Fire X4600 M2 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
238064


Description
This document provides a proving BIOS device scanning order on Galaxy family systems.

Steps to Follow
Refer to the information below.

- X4100
   1. On-board NIC
   2. Slot 0
   3. On-board SAS controller
   4. Slot 1

- X4100M2
   1. PCIE Slot 0
   2. PCIE Slot 1
   3. On-board NIC
   4. On-board SAS controller
   5. USB

- X4200
   1. On-board NIC
   2. Slot 0
   3. On-board SAS controller
   4. Slot 2
   5. Slot 3
   6. Slot 4
   7. Slot 1


- X4200M2
   1. PCIE Slot 0
   2. PCIE Slot 1
   3. PCIE Slot 3
   4. PCIE Slot 4
   5. PCIX Slot 2
   6. On-board NIC
   7. On-board SAS controller
   8. USB


- X4600/X4600M2
   1.  PCI-E slot 2
   2.  PCI-E slot 3
   3.  PCI-E slot 4
   4.  On-board Intel NIC
   5.  PCI-X slot 0
   6.  PCI-X slot 1
   7.  On-board LSI SCSI controller
   8.  PCI-E slot 5
   9.  PCI-E slot 6
  10. PCI-E slot 7
 
See also
Sun Fire X4100/X4200 Servers Product Notes (December 2007) - 819-1162-28
Sun Fire X4100 M2/X4200 M2 Servers Product Notes - 819-5038-22
Sun Fire X4600 Server Product Notes - 819-4347-19
Sun Fire X4600 M2 Server Product Notes - 819-5032-23


Internal Comments
x4100,x4100m2,x4200,x4200m2,x4600,x4600m2,galaxy, BIOS, scanning, order

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.