Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1019274.1 : BIOS device scanning order on Galaxy family systems
PreviouslyPublishedAs 238064 Description This document provides a proving BIOS device scanning order on Galaxy family systems. Steps to Follow Refer to the information below. - X4100 1. On-board NIC 2. Slot 0 3. On-board SAS controller 4. Slot 1 - X4100M2 1. PCIE Slot 0 2. PCIE Slot 1 3. On-board NIC 4. On-board SAS controller 5. USB - X4200 1. On-board NIC 2. Slot 0 3. On-board SAS controller 4. Slot 2 5. Slot 3 6. Slot 4 7. Slot 1 - X4200M2 1. PCIE Slot 0 2. PCIE Slot 1 3. PCIE Slot 3 4. PCIE Slot 4 5. PCIX Slot 2 6. On-board NIC 7. On-board SAS controller 8. USB - X4600/X4600M2 1. PCI-E slot 2 2. PCI-E slot 3 3. PCI-E slot 4 4. On-board Intel NIC 5. PCI-X slot 0 6. PCI-X slot 1 7. On-board LSI SCSI controller 8. PCI-E slot 5 9. PCI-E slot 6 10. PCI-E slot 7 See also Sun Fire X4100/X4200 Servers Product Notes (December 2007) - 819-1162-28 Sun Fire X4100 M2/X4200 M2 Servers Product Notes - 819-5038-22 Sun Fire X4600 Server Product Notes - 819-4347-19 Sun Fire X4600 M2 Server Product Notes - 819-5032-23 Internal Comments x4100,x4100m2,x4200,x4200m2,x4600,x4600m2,galaxy, BIOS, scanning, order Attachments This solution has no attachment |
||||||||||||
|