Asset ID: |
1-71-1019148.1 |
Update Date: | 2011-04-26 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1019148.1
:
How to login to Sun Blade Server Modules in a Sun Blade[TM] 6000/6048 Modular System
Related Items |
- Sun Blade T6300 Server Module
- Sun Blade X6220 Server Module
- Sun Blade X6450 Server Module
- Sun Blade T6320 Server Module
- Sun Blade X6250 Server Module
- Sun Blade 6048 System
|
Related Categories |
- GCS>Sun Microsystems>Servers>Blade Servers
|
PreviouslyPublishedAs
235961
Applies to:
Sun Blade 6048 System
Sun Blade T6300 Server Module
Sun Blade T6320 Server Module
Sun Blade X6220 Server Module
Sun Blade X6250 Server Module
All Platforms
Goal
DescriptionThis document describes how to login to a blade server module via the Chassis Management Module (CMM)
Symptoms
- Can't connect
- Can't login
Purpose/ScopeThis document shows examples of logging in to the following blade server modules via a CMM:
Sun Blade X6220 Server ModuleSun Blade X6250 Server ModuleSun Blade T6300 Server Module It does not cover logging in via the server's network (using telnet,ssh, etc)
Solution
Steps to FollowSteps to follow to login to a Blade Server Module via the Chassis Monitoring Module (CMM) on a Sun Blade 6000/6048 chassis
Sun Blade
X6220 Server Module
# ssh -l root blade_6000_cmm
Password:
Sun(TM) Integrated Lights Out Manager
Version
2.0.3.2
Copyright 2007 Sun Microsystems, Inc. All rights
reserved.
Use is subject to license terms.
-> show
/CH/BL0
/CH/BL0
Targets:
SP
SEEPROM
Properties:
type = Blade
fru_part_number = 501-7324-04
fru_serial_number = 0000000-0711ZG00HU
fru_name =
ASSY,BD,GEMINI,X6220
Commands:
cd
show
-> start /CH/BL0/SP/cli
Are you sure you want to start /CH/BL0/SP/cli (y/n)? y
start: Connecting to /CH/BL0/SP/cli using Single Sign On
Sun(TM) Integrated Lights Out Manager
Version 2.0.3.2
Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
Warning: password is set
to factory default.
-> start
/SP/console
Are you sure you want to start /SP/console (y/n)?
y
Serial console started. To stop, type ESC (
x6220a- console login:
Sun Blade X6250
Server Module
# ssh -l root blade_6000_cmm
Password:
Sun(TM) Integrated Lights Out Manager
Version
2.0.3.2
Copyright 2007 Sun Microsystems, Inc. All rights
reserved.
Use is subject to license terms.
-> cd
BL3
/CH/BL3
-> show
/CH/BL3
Targets:
SP
SEEPROM
Properties:
type = Blade
fru_part_number = 501-7376-02
fru_serial_number =
0000000-7001
fru_name = ASSY,BD,WOLF,X6250
Commands:
cd
show
->
start /CH/BL3/SP/cli
Are you sure you want to start
/CH/BL3/SP/cli (y/n)? y
start: Connecting to
/CH/BL3/SP/cli as user root
start: Change the "user"
property to connect as a different user
[email protected]'s
password:
Sun Microsystems Embedded Lights Out Manager
Copyright 2006 Sun Microsystems, Inc. All rights reserved.
Firmware Version: 4.0.51
SMASH Version: v1.0.0
Hostname: SUNSP001B242D495D
IP address: 10.12.9.207
MAC address: 00:1B:24:2D:49:5D
-> show
/
Targets:
SP
SYS
CH
Properties:
Target
Commands:
show
cd
-> start /SP/AgentInfo/Console
console
activate successful
press ESC+( to terminate session...
x6250a
console login:
Sun Blade T6300 Server Module
#
ssh -l root blade_6000_cmm
Password:
Sun(TM)
Integrated Lights Out Manager
Version 2.0.3.2
Copyright
2007 Sun Microsystems, Inc. All rights reserved.
Use is subject
to license terms.
-> show /CH/BL6
/CH/BL6
Targets:
SYS
SP
SEEPROM
Properties:
type =
Blade
fru_name =
ASSY,BLADE,T6300,8-CORE,1.4GHZ
fru_part_number = 541-2320-04
fru_serial_number = 0000000-0748UM03DK
Commands:
cd
show
-> start /CH/BL6/SP/cli
Are you sure you
want to start /CH/BL6/SP/cli (y/n)? y
start:
Connecting to /CH/BL6/SP/cli as user root
start: Change the "user"
property to connect as a different user
Copyright 2007 Sun
Microsystems, Inc. All rights reserved.
Use is subject to
license terms.
Sun(tm) Advanced Lights Out Manager CMT
v1.6.2
Please login: admin
Please Enter password:
*********
sc> console
Enter #. to return to
ALOM.
{0} ok
{0} ok
sc>
sc>
logout
start: The session with /CH/BL6/SP/cli has
ended.
->
Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective @ domains. To notify content owners of a knowledge gap contained in this document, and/or prior to
updating this document, please contact the domain engineers that are managing this document via the
“Document Feedback” alias(es) listed below:
Domain Lead: [email protected]
Feedback Alias: [email protected]
normalized, blade,6000,6048,x6220,x6250,T6300,how to,login
Change History
Date: 2009-11-18
User name: Brian Jackson
Action: Updated
Comments: Currency check, audited by Dencho Kojucharov, Entry-Level SPARC Content Team
Attachments
This solution has no attachment