Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1019148.1
Update Date:2011-04-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1019148.1 :   How to login to Sun Blade Server Modules in a Sun Blade[TM] 6000/6048 Modular System  


Related Items
  • Sun Blade T6300 Server Module
  •  
  • Sun Blade X6220 Server Module
  •  
  • Sun Blade X6450 Server Module
  •  
  • Sun Blade T6320 Server Module
  •  
  • Sun Blade X6250 Server Module
  •  
  • Sun Blade 6048 System
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Blade Servers
  •  

PreviouslyPublishedAs
235961


Applies to:

Sun Blade 6048 System
Sun Blade T6300 Server Module
Sun Blade T6320 Server Module
Sun Blade X6220 Server Module
Sun Blade X6250 Server Module
All Platforms

Goal

Description
This document describes how to login to a blade server module via the Chassis Management Module (CMM)

Symptoms
  • Can't connect
  • Can't login
Purpose/Scope

This document shows examples of logging in to the following blade server modules via a CMM:

Sun Blade X6220 Server Module
Sun Blade X6250 Server Module
Sun Blade T6300 Server Module

 It does not cover logging in via the server's network (using telnet,ssh, etc)

Solution

Steps to Follow

Steps to follow to login to a Blade Server Module via the Chassis Monitoring Module (CMM) on a Sun Blade 6000/6048 chassis

Sun Blade X6220 Server Module

# ssh -l root blade_6000_cmm
Password:

Sun(TM) Integrated Lights Out Manager

Version 2.0.3.2

Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

-> show  /CH/BL0

/CH/BL0
   Targets:
   SP
   SEEPROM

   Properties:
   type = Blade
   fru_part_number = 501-7324-04
   fru_serial_number = 0000000-0711ZG00HU
   fru_name = ASSY,BD,GEMINI,X6220

   Commands:
   cd
   show

-> start /CH/BL0/SP/cli
Are you sure you want to start /CH/BL0/SP/cli (y/n)? y
start: Connecting to /CH/BL0/SP/cli using Single Sign On

Sun(TM) Integrated Lights Out Manager

Version 2.0.3.2

Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

Warning: password is set to factory default.


-> start /SP/console
Are you sure you want to start /SP/console (y/n)? y

Serial console started.  To stop, type ESC (

x6220a- console login:


Sun Blade X6250 Server Module

# ssh -l root blade_6000_cmm
Password:

Sun(TM) Integrated Lights Out Manager

Version 2.0.3.2

Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

-> cd BL3
/CH/BL3

-> show

/CH/BL3
   Targets:
   SP
   SEEPROM

   Properties:
   type = Blade
   fru_part_number = 501-7376-02
   fru_serial_number = 0000000-7001
   fru_name = ASSY,BD,WOLF,X6250
   Commands:
   cd
   show

-> start /CH/BL3/SP/cli
Are you sure you want to start /CH/BL3/SP/cli (y/n)? y
start: Connecting to /CH/BL3/SP/cli as user root
start: Change the "user" property to connect as a different user
[email protected]'s password:

Sun Microsystems Embedded Lights Out Manager
Copyright 2006 Sun Microsystems, Inc. All rights reserved.

Firmware Version: 4.0.51
SMASH Version: v1.0.0

Hostname: SUNSP001B242D495D
IP address: 10.12.9.207
MAC address: 00:1B:24:2D:49:5D

-> show
 /
   Targets:
       SP
       SYS
       CH
   Properties:
   Target Commands:
       show
       cd

-> start /SP/AgentInfo/Console

console activate successful
press ESC+( to terminate session...

x6250a console login:

Sun Blade T6300 Server Module

# ssh -l root blade_6000_cmm
Password:

Sun(TM) Integrated Lights Out Manager

Version 2.0.3.2

Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.

-> show /CH/BL6

 /CH/BL6
    Targets:
        SYS
        SP
        SEEPROM

    Properties:
        type = Blade
        fru_name = ASSY,BLADE,T6300,8-CORE,1.4GHZ
        fru_part_number = 541-2320-04
        fru_serial_number = 0000000-0748UM03DK

    Commands:
        cd
        show

-> start /CH/BL6/SP/cli
Are you sure you want to start /CH/BL6/SP/cli (y/n)? y

start: Connecting to /CH/BL6/SP/cli as user root
start: Change the "user" property to connect as a different user

Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
Use is subject to license terms.


Sun(tm) Advanced Lights Out Manager CMT v1.6.2

Please login: admin
Please Enter password: *********


sc> console
Enter #. to return to ALOM.

{0} ok
{0} ok

sc>
sc> logout
start: The session with /CH/BL6/SP/cli has ended.

->


Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective @ domains. To notify content owners of a knowledge gap contained in this document, and/or prior to
updating this document, please contact the domain engineers that are managing this document via the
“Document Feedback” alias(es) listed below:

Domain Lead: [email protected]
Feedback Alias: [email protected]



normalized, blade,6000,6048,x6220,x6250,T6300,how to,login

Change History
Date: 2009-11-18
User name: Brian Jackson
Action: Updated
Comments: Currency check, audited by Dencho Kojucharov, Entry-Level SPARC Content Team



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback