Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018971.1
Update Date:2010-10-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018971.1 :   V440 Device Tree Layout [Video]  


Related Items
  • Sun Fire V440 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • GCS>Support>KM>Content>Video
  •  

PreviouslyPublishedAs
231363


Applies to:

Sun Fire V440 Server
All Platforms

Goal

This document discusses the Sun Fire V440 server device layout from the Solaris operating environment.

Available for this topic, a Video Tutorial; Brief how-to video tutorials that provide step-by-step instructions answering Sun's most frequently asked questions. View the video answer and/or follow the detailed instructions below.

Video - Device Layout in a V440 Server (04:30)


Sunsolve users must download the attachment to view the video.

Solution

The first step to get a look at the Sun Fire V440 server device layout is to enter the command cd /etc. This is the directory from which you can view the layout of the system.

Next, enter more path_to_inst. Please note that you can also use the cat command to view the contents of the file. The path_to_inst file gives you the layout of devices on the server. Do delete the path_to_inst file on the system. Deleting the file prevents the server from booting. It is suggested that you keep a backup of the path_to_inst file in case of accidental file deletion.

We ill highlight only the important information that you need to look at when reviewing the /etc/path_to_inst file.

As you can see, the first piece is the onboard psycho chip on pci@1c,600000 and the network chip which is on the pci@1c,600000, note that ce is highlighted in the file entry. This example also shows that it has four network ports on the motherboard.

The output shown displays all of the I2C information pertaining to the system. The I2C is the monitoring feature on the system on the port helps monitor temperature and make sure there are no faults.

Additionally it displays information about the power supply, the memory, the CPU and its temperature. It also displays clock information such as whether or not the clock is operating.

If there is an array listed in the system the path_to_inst file, it will be listed out as array information and include data such as the disk and its associated number. This example shows information for a Sun Fire V440 server with only one disk, pci@1f,700000/scsi@2/sd@0,0 but if the machine had other disks, the file would contain additional disk information such as scsi@2/disk@1,0 2,0 3,0 and if it is off in the array. Depending on where the SCSI card is installed in the PCI slot these values can also be displayed as pci@1 or pci@2.

The output also shows this system is populated with four UltraSPARC IIIi CPUs in slots 0, 1, 2 and 3.

 

V440 Device Tree Layout

/pci@1c,600000. . . . . . . . . . . . . . . . . . . . . PCI 1a (pcisch)
/pci@1c,600000/network@2. . . . . . . . . . . . . . . .  Cassini Net 0 (ce)
/pci@1c,600000/pci@1. . . . . . . . . . . . . . . . . .  66MHz PCI slot 5
/pci@1d,700000. . . . . . . . . . . . . . . . . . . . . PCI 1b (pcisch)
/pci@1d,700000/pci@2. . . . . . . . . . . . . . . . . .  66MHz PCI slot 2
/pci@1d,700000/pci??? . . . . . . . . . . . . . . . . .  66MHz PCI slot 4
/pci@1e,600000. . . . . . . . . . . . . . . . . . . . . PCI 2a (pcisch)
/pci@1e,6 00000/isa@7. . . . . . . . . . . . . . . . . .  Southbridge (ebus)
/pci@1e,600000/isa@7/power@0,800. . . . . . . . . . . .   power
/pci@1e,600000/isa@7/rmc-comm@0,3e8 . . . . . . . . . .   ALOM comm (rmc_comm)
/pci@1e,600000/isa@7/i2c@0,320. . . . . . . . . . . . .   I2C bus (pcf8584)
/pci@1e,600000/isa@7/i2c@0,320/temperature@0,30 . . . .    Temp CPU0 (max1617)
/pci@1e,600000/isa@7/i2c@0,320/cpu-fru-prom@0,be. . . .    CPU0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,b6. . . . . .    DIMM0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,b8. . . . . .    DIMM2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,ba. . . . . .    DIMM1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,bc. . . . . .    DIMM3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/temperature@0,64 . . . .    Temp CPU1 (max1617)
/pci@1e,600000/isa@7/i2c@0,320/cpu-fru-prom@0,ce. . . .    CPU1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,c6. . . . . .    DIMM0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,c8. . . . . .    DIMM2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,ca. . . . . .    DIMM1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,cc. . . . . .    DIMM3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/temperature@0,80 . . . .    Temp CPU2 (max1617)
/pci@1e,600000/isa@7/i2c@0,320/cpu-fru-prom@0,de. . . .    CPU2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,d6. . . . . .    DIMM0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,d8. . . . . .    DIMM2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,da. . . . . .    DIMM1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,dc. . . . . .    DIMM3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/temperature@0,90 . . . .    Temp CPU3 (max1617)
/pci@1e,600000/isa@7/i2c@0,320/cpu-fru-prom@0,ee. . . .    CPU3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,e6. . . . . .    DIMM0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,e8. . . . . .    DIMM2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,ea. . . . . .    DIMM1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/dimm-spd@0,ec. . . . . .    DIMM3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/power-supply-fru-prom@0,70  PSU2 seeprom
/pci@1e,600000/isa@7/i2c@0,320/power-supply-fru-prom@0,72  PSU3 seeprom
/pci@1e,600000/isa@7/i2c@0,320/power-supply-fru-prom@0,c0  PSU0 seeprom
/pci@1e,600000/isa@7/i2c@0,320/power-supply-fru-prom@0,c2  PSU1 seeprom
/pci@1e,600000/isa@7/i2c@0,320/pdb-fru-prom@0,7c. . . .    Power Distr Brd seeprom
/pci@1e,600000/isa@7/i2c@0,320/motherboard-fru-prom@0,a2   Motherboard seeprom
/pci@1e,600000/isa@7/i2c@0,320/rmc-fru-prom@0,a6. . . .    ALOM seeprom
/pci@1e,600000/isa@7/i2c@0,320/scsi-fru-prom@0,a8 . . .    SCSI I/F Brd seeprom
/pci@1e,600000/isa@7/i2c@0,320/alarm-fru-prom@0,ac. . .    Alarm card seeprom
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,38. . . . . . . .    PSU0 Control & Status
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,3a. . . . . . . .    PSU1 Control & Status
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,3c. . . . . . . .    PSU0 & 1 Status (on PDB)
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,42. . . . . . . .    KeySwitch (pca9556)
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,44. . . . . . . .    System Status (pca9556)
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,46. . . . . . . .    Disk LEDs (pca9556)
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,48. . . . . . . .    Rear LEDs (pca9556)
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,e0. . . . . . . .    PSU2 Control & Status
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,e2. . . . . . . .    PSU3 Control & Status
/pci@1e,600000/isa@7/i2c@0,320/gpio@0,e4. . . . . . . .    PSU2 & 3 Status (on PDB)
/pci@1e,600000/isa@7/i2c@0,320/clock-generator@0,d2 . .    PCI Clock Gen (ics951601)
/pci@1e,600000/isa@7/serial@0,3f8 . . . . . . . . . . .   TTYa via SC (su)
/pci@1e,600000/isa@7/serial@0,2e8 . . . . . . . . . . .   TTYb (su)
/pci@1e,600000/pmu@6. . . . . . . . . . . . . . . . . .  Southbridge (pmubus)
/pci@1e,600000/pmu@6/gpio@8a. . . . . . . . . . . . . .   (pmugpio)
/pci@1e,600000/pmu@6/lomwd@cc . . . . . . . . . . . . .   LOM Watchdog (lomwd)
/pci@1e,600000/usb@a. . . . . . . . . . . . . . . . . .  Southbridge USB0,1 (ohci)
/pci@1e,600000/usb@b. . . . . . . . . . . . . . . . . .  Southbridge USB2,3 (ohci)
/pci@1e,600000/pci??? . . . . . . . . . . . . . . . . .  33MHz PCI slot 0
/pci@1e,600000/pci??? . . . . . . . . . . . . . . . . .  33MHz PCI slot 1
/pci@1e,600000/pci??? . . . . . . . . . . . . . . . . .  33MHz PCI slot 3
/pci@1e,600000/ide@d. . . . . . . . . . . . . . . . . .  Southbridge (uata)
/pci@1e,600000/ide@d/cdrom@0,0:f. . . . . . . . . . . .   cdrom/DVD
/pci@1f,700000. . . . . . . . . . . . . . . . . . . . . PCI 2b (pcisch)
/pci@1f,700000/network@1. . . . . . . . . . . . . . . .  Cassini Net 1 (ce)
/pci@1f,700000/scsi@2 . . . . . . . . . . . . . . . . .  SCSIa - Internal Drives (mpt)
/pci@1f,700000/scsi@2/disk@0,0. . . . . . . . . . . . .   disk 0 (sd)
/pci@1f,700000/scsi@2/disk@1,0. . . . . . . . . . . . .   disk 1 (sd)
/pci@1f,700000/scsi@2/disk@2,0. . . . . . . . . . . . .   disk 2 (sd)
/pci@1f,700000/scsi@2/disk@3,0. . . . . . . . . . . . .   disk 3 (sd)
/pci@1f,700000/scsi@2,1 . . . . . . . . . . . . . . . .  SCSIb - External SCSI (mpt)

 



Product
Sun Fire V440 Server


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.