Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1018859.1 : Sun Fire[TM] V440 server: On-board LSI1030 controller - how to show the firmware version
PreviouslyPublishedAs 230658 Description This document describes how to confirm the firmware version, for a Sun Fire[TM] V440 server, on-board LSI1030 SCSI RAID controller. Steps to Follow To confirm the current firmware version for Sun Fire V440 server onboard LSI1030 SCSI RAID controller, use the following method: # prtconf -vp | grep firmware-version Below is an output example showing firmware version 1.03.07.00 : # prtconf -vp | grep firmware-version firmware-version: '1.03.07.0' ^^^^^^^^^^
Note: Other methods for collecting the Firmware version such as grep'ing
Product Sun Fire V440 Server Netra 440 Server LSI1030, mpt, raidctl, 115662-01, 115662, v440 firmware-version, u320 scsi controller Previously Published As 72786 Change History Date: 2009-11-23 User Name: Anthony Rulli Action: Updated Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team Version: 0 Date: 2006-01-17 User Name: 18392 Action: Update Started Comment: SSH AUDIT Version: 0 Attachments This solution has no attachment |
||||||||||||
|