Solution Type  Technical Instruction Sure

Solution  1018859.1 :   Sun Fire[TM] V440 server: On-board LSI1030 controller - how to show the firmware version  


Related Items
  • Sun Fire V440 Server
  •  
  • Sun Netra 440 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
230658


Description
This document describes how to confirm the firmware version, for a Sun Fire[TM]
V440 server, on-board LSI1030 SCSI RAID controller.


Steps to Follow
To confirm the current firmware version for Sun Fire V440 server onboard
LSI1030 SCSI RAID controller, use the following method:
# prtconf -vp | grep firmware-version

Below is an output example showing firmware version 1.03.07.00 :

# prtconf -vp | grep firmware-version
firmware-version:  '1.03.07.0'
^^^^^^^^^^ 

Note: Other methods for collecting the Firmware version such as grep'ing
messages or dmesg are unreliable can give confusing results due to changes
in Solaris[TM] 9 and Solaris[TM] 10. The above prtconf method is the only reliable
method.




Product
Sun Fire V440 Server
Netra 440 Server

LSI1030, mpt, raidctl, 115662-01, 115662, v440 firmware-version, u320 scsi controller
Previously Published As
72786

Change History
Date: 2009-11-23
User Name: Anthony Rulli
Action: Updated
Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team
Version: 0
Date: 2006-01-17
User Name: 18392
Action: Update Started
Comment: SSH AUDIT
Version: 0


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback