PreviouslyPublishedAs 230486 Description This article tells you what to do if you have multiple T3+'s (referenced below as T3B) and want to centralize the syslog's in one admin server without mixing them in the same /var/adm/messages.t3 file. Steps to Follow Note: This feature was only tested with T3B running the F/W 2.1 or higher. The default "local" level used by the T3B is 7. That means that all the events inside the T3B are sent out (if the T3B's syslog is properly configured) through the local7. However, with T3B and the appropriate F/W, you can set the local level (from 0 to 7) to be used to send the events out. Therefore, you can specify a different local level for each of your T3B's and configure your syslog.conf file on your server to gather the events into the appropriate files. The following configuration was used for the example below: - 4x T3B (running the F/W 2.1 or higher): T3b0, T3b1, T3b2, T3b3 - 1x administration server: saturn (IP 192.168.3.1) T3b0's syslog file *.warn @192.168.3.1 local0 T3b1's syslog file *.warn @192.168.3.1 local1 T3b2's syslog file *.warn @192.168.3.1 local2 T3b3's syslog file *.warn @192.168.3.1 local3 saturn's syslog file local0.* /var/adm/messages.T3b0 local1.* /var/adm/messages.T3b1 local2.* /var/adm/messages.T3b2 local3.* /var/adm/messages.T3b3 Product Sun StorageTek T3+ Array Sun StorageTek T3 Array Internal Comments For internal Sun use only. [email protected], [email protected] error log, disks, storage, error messages, T3, T4, 6120 Previously Published As 50623 Change History Date: 2004-06-04 User Name: C149439 Action: Approved Comment: Placed product name in the beginning of title. Edited text. Gail Waldron Version: 0 Date: 2004-05-28 User Name: C149439 Action: Accepted Comment: Version: 0 Date: 2004-05-28 User Name: 71066 Action: Approved Comment: I'm passing this doc to the final review stage directly because: 1--The technical part didn't change. I've not done any change. 2--I've just changed the expiration date from 2004 to 2005. 3--This doc is already published but due to technical reason, the contents got corrupted when I took it into my draft queue for modification. The dev team recovered the situation and now I would like to move it out from my draft queue. Thanks Nicolas Version: 0 Attachments This solution has no attachment |
||||||||||||
|