Solution Type Technical Instruction Sure Solution 1018648.1 : Instructions for Direct Access to the Sun Fire[TM] V20z/V40z Service Processor
PreviouslyPublishedAs 230347 Description These are instructions to connect and configure the Service Processor; please reference the V20z/V40z Server Management Guide for additional information. PLEASE NOTE: In order to connect to the Service Processor, you must use a network connection as well as be able to open an "ssh" connection. Steps to Follow Instructions for Direct Access to the Sun Fire[TM] V20z/V40z Service Processor
Step 1.
Step 2.
Step 3.
1.Use the LCD panel and select SP menu. # ssh <sp-ipaddress> -l setup You will then be prompted to setup the new service account(username) and password. If a username and password already exists, then make sure that it was not created by the customer. You can clear the username and password by using the Operator Panel(LCD). Navigate to the SP menu and select Use defaults option. Note: All the current network and user settings for the SP will be set to factory defaults.
Step 4.
# ssh -l <username> <SP ip-address> You will then be prompted for the password. Once authenicated, you will be at the loghost prompt. Example: loghost# Once connected, you can now run commands such as diags, inventory, sp, and platform to manage or troubleshoot the server. Related product documentation Product Sun Fire V40z Server Sun Fire V20z Server Sun Fire V20z Compute Grid Rack System V20z, V40z, ssh, SP, service processor, connect, platform, diags, inventory, nsv, network share volume, NFS, server, mount Previously Published As 79857 Change History Date: 2010-05-26 User Name: [email protected] Action: Checked for currency Comment: Updated to include link to current product documentation. Attachments This solution has no attachment |
||||||||||||
|