Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018453.1
Update Date:2010-07-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018453.1 :   IntelliStore - How to Configure the Destination SNMP/E-mail Address  


Related Items
  • Sun Storage 5800 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Fixed Content Disk
  •  

PreviouslyPublishedAs
230041


Description
IntelliStore
SNMP
MIB
How to Configure the Destination SNMP/E-mail Address

Steps to Follow
From the GUI:
  1. Expand the System Management node from the tree view pane and click on View Logs.
  2. From the action pane, select the drop-down Actions box and choose Edit Log.
  3. Type in the new SNMP destination address and/or E-mail destination for event notification messages as required in the following format:

    snmpAddress
    :n:*,snmpAddress:n:*

    where snmpAddress is a valid IP address such as 127.0.0.1, n is the alert level and * is the scope. The alert level and the scope must be separated by columns. You can specify multiple E-mail addresses, separated by commas.

    Note: The maximum number of characters is 40.

    You can specify any of the following alert levels:

    -
    Emergency :1
    - Alert :2
    - Critical :3
    - Error :4
    - Warning :5
    - Notification :6
    - Information :7
    - Info2 :8
    - Debug :9

  4. Click Apply.