Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018190.1
Update Date:2010-10-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018190.1 :   Sun StorEdge[TM] T3 loop card failures  


Related Items
  • Sun Storage T3 Array
  •  
  • Sun Storage T3+ Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
229548


Description
In order to provide you the most accurate fix, please validate that each statement under the symptoms below is true for your environment. These symptoms will hyperlink you into a relevant content that will 1) tell you how to validate the listed symptom and 2) how to fix the symptom if it is true for your environment. The listed symptoms are ordered in the most appropriate sequence to isolate the issue and be certain about the related fix. Please do not skip a step.

Symptoms:

- loop card disabled

- loop card offline



Steps to Follow
Sun StorEdge[TM] T3 loop card failures

NOTE: This is a sub-set of <Document: 1018272.1> "Troubleshooting Sun StorEdge[TM] T3 Configuration."  This document will help with faulted loop cards based on similar "fru stat" output below:

LOOP    STATUS   STATE       MODE        CABLE1    LB  CABLE2    LB  TEMP
------  -------  ----------  -------     --------- --  --------- --  ----
u1l1    ready    enabled     master      -         -   installed 10  27
u1l2    ready    
disabled
    slave       -         -   installed 11  33
u2l1    ready    enabled     master      installed 10  -         -   27
u2l2    offline

Troubleshooting Steps:

1.  Enable loop card with "enable u#[1|2]" command.

Example:

storage-t3b:/:<3>enable u1l2

2.  Verify that the loop card is now ready and enabled with the "fru stat" command.

NOTE:  Wait about 1 minute before running "fru stat" as to allow the array to recover.

3.  If the loop card is still not ready enabled, then replace loop card.



Product
Sun StorageTek T3+ Array
Sun StorageTek T3 Array

Internal Comments
This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below:

[email protected]




Place Sun Internal-Use Only content here. This content will be
published to internal SunSolve[SM] only.


T3, T3+, normalized, loop card
Previously Published As
86657

Change History
Date: 2006-08-18
User Name: 7058
Action: Approved
Comment: Cross-reference re-done.
Format reworked.
Spell ck OK
Trademarking done.
OK to publish.
Version: 3


Date: 2006-08-17
User Name: 123825
Action: Approved
Comment: t3 norm
Version: 0
Date: 2006-08-17
User Name: 78962
Action: Approved
Comment: t3 norm
Version: 0
Date: 2006-08-15
User Name: 78962
Action: Created
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.