Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1018136.1 : Sun StorEdge[TM] A5x00 array: Internal Addressing
PreviouslyPublishedAs 229476 Description This document lists the host target address assignments for each Box ID in a hub or daisy-chained configuration. The Box ID, on which the target address is based, is set on the Front Panel Module (FPM). Not all the 127 allowable device addresses per loop are used. Steps to Follow Sun StorEdge[TM] A5x00 array: Internal Addressing Target assignments for the A5000/A5100 array
Target assignments for the A5200 array
The formula used to calculate the target numbers is: (BoxID x 32) + (Backplane# x 16) + (Disk Slot #) = Target ID In this formula,
Product Sun StorageTek A5200 Array Sun StorageTek A5000 Array Sun StorageTek A5100 Array A5x00, A5200, photon, target, addressing, Box ID, FPM Previously Published As 75284 Change History Date: 2005-01-19 User Name: 25440 Action: Approved Comment: Publishing. Version: 4 Date: 2005-01-19 User Name: 25440 Action: Accept Comment: Version: 0 Date: 2005-01-19 User Name: 89273 Action: Approved Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||
|