Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1018048.1 : How to identify a Sun Fire[TM] v440 system board part number and dash level using Solaris / ALOM commands
PreviouslyPublishedAs 229354 Description Sun Fire[TM] V440 and Netra[TM] 440 systems using a specific networking configuration may unexpectedly reset. This document will show users how to verify the system board Part Number and Dash level using Solaris[TM] commands and ALOM commands. Steps to Follow The fix for the unexpected resets using specific network configurations is coming from a new system board, and also Engineering Change Order (ECO) to the existing system board. Once these boards are available, customer's will want to know how they can verify if their system requires a system board replacement. The affected system board has a part number: 501-6344 with DASH level of 09 and below, the DASH 10 will already have the fix. The new system board will have part number: 501-6910 DASH LEVEL 01. From Solaris execute the following command: # prtfru -x | more <Container name="system-board"> <ContainerData> <Segment name="SD"> <ManR> <UNIX_Timestamp32 value="Sat Jun 28 18:32:10 EDT 2003"/> <Fru_Description value="ASSY,A42,MOTHERBOARD"/> <Manufacture_Loc value="Toronto, Ontario, Canada"/> <Sun_Part_No value="5016344"/> <-- SYSTEM BOARD PART NUMBER <Sun_Serial_No value="006026"/> <Vendor_Name value="Celestica"/> <Initial_HW_Dash_Level value="06"/> <-- DASH LEVEL <Initial_HW_Rev_Level value="50"/> <Fru_Shortname value="A42_MB"/> </ManR> <SpecPartNo value="885-0060-08"/> From the Advanced Lights Out Management prompt (sc>): NOTE: You'll need to be in a window that scrolls, you can not stop the output at the ALOM prompt. sc>showfru FRU_PROM at MB.SEEPROM Manufacturer Record Timestamp: SAT JUN 28 22:32:10 UTC 2003 Description: ASSY,A42,MOTHERBOARD Manufacture Location: Toronto, Ontario, Canada Sun Part No: 5016344 <-- SYSTEM BOARD PART NUMBER Sun Serial No: 006026 Vendor: Celestica Initial HW Dash Level: 06 <-- DASH LEVEL Initial HW Rev Level: 50 Shortname: A42_MB Product Netra 440 Server Netra 440 (AC) Server Sun Fire V440R Server Sun Fire V440 Server Internal Comments For internal Sun use only. Reference FCO# A0245-1 V440, 440, reset, unexpected, system board, alom Previously Published As 80008 Change History Date: 2009-11-23 User name: Dencho Kojucharov Action: Updated Comments: Currency check, audited by Dencho Kojucharov, Entry-Level SPARC Content Lead Date: 2005-01-18 User Name: 71396 Action: Approved Comment: Performed final review on article. Updated part of article per request of author. Minor typo. Update product trademarking. Small formatting change. No other changes required. Publishing. Version: 3 Date: 2005-01-18 User Name: 71396 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|