Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017949.1
Update Date:2009-01-27
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017949.1 :   Sun StorEdge[TM] 3310/3510/3511 Firmware: View and edit logical drive menu for firmware 4.xx  


Related Items
  • Sun Storage 3310 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
229218


Description
The 4.xx firmware introduces some additional columns to the "view and edit logical drive" table. This document defines these changes.

Steps to Follow
"view and edit logical drives" from the Main Menu:
____________________________________________________________________________
| LG   |ID   |LV  |RAID   |Size(MB)   |Status 1|2|3|O|C|#LN|#SB|#FL|NAME    |
|---------------------------------------------------------------------------|
|      |     |    |       |           |        | | | | |   |   |   |        |
|---------------------------------------------------------------------------|
LG - The logical group number
ID - The unique identifier of each logical drive
LV - The number of the logical volume, if the LG is a member of a logical volume
RAID - The RAID type
Size - The size of the logical drive, in megabytes (MB)
Status (1, 2, 3) - Each provides a particular status for the logical drive.
1 - Good        = The logical drive is in a good state
Creating    = The logical drive is being initialized
DRV Failed  = Disk in the logical drive has failed
DRV Absent  = Missing drive at power-on or missing after a controller reset
Incomplete  = Too many disks are absent to create a valid logical drive
2 - I = Currently initializing the logical drive
A = Currently adding a drive to the logical drive
E = Currently expanding a logical drive
3 - R = Rebuilding the logical drive.  This is typically due to a disk faiure
P = A parity regeneration is being performed on the logical drive.
O - The optimized stripe depth for the logical drive.
2 = 4 Kbyte
3 = 8 Kbyte
4 = 16 Kbyte
5 = 32 Kbyte
6 = 64 Kbyte
7 = 128 Kbyte
8 = 256 Kbyte
C - Displays the cache setting for the logical drive
B = Write-back cache enabled
T = Write-through cache enabled
#LN - The number of drives that are online
#SB - The number of drives that are stand-by drives
#FL - The number of failed drives
Name - Name for the logical drive


Product
Sun StorageTek 3310/3510/3511 Firmware 4.11 Upgrade
Sun StorageTek 3310 SCSI Array

Minnow, minnow, 3310, 3510, 3511, firmware, Firmware, 4, 4.xx, 4., view, edit, logical, drives
Previously Published As
80986

Change History
Date: 2005-04-11
User Name: 25440
Action: Approved
Comment: Audience changed to contract per FvF http://kmo.central/howto/FvF.html
Added "Sun StorEdge[TM] 3310/3510/3511 Firmware" to title (taken from the Product field) as a clue to what this document is about. Publishing.
Version: 3
Date: 2005-04-11
User Name: 25440
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback