Asset ID: |
1-71-1017877.1 |
Update Date: | 2011-04-13 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1017877.1
:
Sun StorageTek[TM] 2540 (FC) Firmware Matrix
Related Items |
- Sun Storage 2540 Array
- Sun Storage Common Array Manager (CAM)
|
Related Categories |
- GCS>Sun Microsystems>Storage - Disk>Modular Disk - 2xxx Arrays
|
PreviouslyPublishedAs
229121
This article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions.
In this Document
Goal
Solution
Applies to:
Sun Storage 2540 Array
Sun Storage Common Array Manager (CAM) - Version: 5.1 and later [Release: 5.0 and later]
All Platforms
Goal
This article documents Sun StorageTek 2540 (FC) Array's components
firmware baseline bundled in each corresponding CAM release and patched
versions.
This document assumes the relevant array product is managed with Common
Array Manager. This reference can be used by end-user and all levels
of support personnel for purpose of verifying component firmware and
management software compatibility.
For instructions to download CAM, please refer to <Document 1296274.1>
How to Download Common Array Manager (CAM) Software and Patches.
Solution
NOTE: Firmware shown as "controlled" are not publicly available and is only
provided on a case-by-case basis as deemed necessary by support services.
a
Release 1.0 was for 2540 GA.
b
Patches 12748[678]-xx are for CAM 5.1.x only and was released independent of CAM 6.0.
Take note that CAM 6.0 has LOWER rev of firmware, and these patches cannot be applied
directly on CAM 6.0 due to packaging differences (dir structure changed).
c
Patches 1282{69|70|71}-01 are for CAM 6.0 only and contains the same firmware as that
of CAM 5.1.x patches 12748[678]-xx.
d
Patches 13729[456]-01, new controller firmware for 48 drives support.
e
Patches 13793[456]-01, controller network issue bug fix, for CAM 6.1.0.
f
Patches 13793[456]-02, controller network issue bug fix to include 6140, firmware for 2500 same as -01.
g
Patches 13903[456]-01, controller network issue bug fix for 2500 and 6140 for CAM 6.1.1.
h
CAM 6.2.0 supports and bundles 7.35 firmware for 2500 series arrays,
however upgrade utility is a separate download. This firmware upgrade can be done by customer.
i
Patches 14006[012]-01,
2530_exmoor.properties fix for CR6762669 Unable to upgrade NVSRAM firmware on a simplex 2530 array;
requires CAM core patch 14006[456]-01.
j
7.35.10.13 contains the fix for SA256288 but was not bundled in CAM 6.4.0.
k
7.35.44.10 fixes SA256288 and supersedes 7.35.10.13.
l CAM 6.6.0.11 host types do not match array's
host region (CR6935284), affecting 2500, 6140, 6180, 6540, 6580/6780.
This may result in either new mappings selecting the wrong host region,
or user confused by the display and change existing mappings which was
correct, to become wrong. CAM 6.6.0.12 through patch 14147[456]-01 was
specifically released to resolve this bug.
|
Internal website for CAM supported array firmware matrix.
http://tsc-storage.us/products/CAM/matrix.html
This site is typically updated first before being edited for public consumption.
Attachments