Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017377.1
Update Date:2010-02-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017377.1 :   SL8500 - Reserve/Release Status in Multi-Library PTP Configurations  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
228454


Description
Reserve/Release Status in Multi-Library PTP Configurations
SL8500 multi-library configurations connected together in one ACS via PTP's use a series of "Reserve and Release" commands to reserve and release necessary 
resources for inter-library moves. During maintenance activity if the library controller or other library components are rebooted a pending reserve may not
get released.


Steps to Follow
Highly encourage all multiple library configurations to upgrade to 3.72 or above to decrease the necessity of rebooting all libraries in a multiple library complex if one library in the complex is rebooted.

Code change in 3.72 greatly reduces this exposure by reserving resources in smaller increments and it does not reserve the source and destination resources at the initiation of the move request.

In a multi-library complex if the front door must be opened without the use of the SSD or the HBC is reset:


-Vary the associated LSMs offline from HSC or ACSLS.
-Vary the library offline via SLC select; system detail-Library x,0,0,0,0-Transition Request-Take Offline.

Note: Do not use Take Immediately Offline, this option will be removed in next release after 3.72 scheduled for 9/2007.
Before the library goes offline it will complete all pending request and therefore not leave any pending reserves.



Product
Sun StorageTek SL8500 Modular Library System

Internal Comments
Oracle Review 2/2/10, Glen Foley

Status, Release, Reserve, SL8500, Reserve / Release status in multi-library PTP configurations, PTP configuration, Multiple library configuration
Previously Published As
STKKB80400
Product_uuid
885cbe90-bdf8-11db-8069-080020a9ed93

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback