Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1016821.1
Update Date:2010-12-29
Keywords:

Solution Type  Technical Instruction Sure

Solution  1016821.1 :   Tape - Information needed to Escalate a Tape Problem to Support  


Related Items
  • Sun StorageTek 7430 Tape Library
  •  
  • Sun Storage L7 Tape Autoloader
  •  
  • Sun Storage L8 Tape Autoloader
  •  
  • Sun StorageTek 9940B Tape Drive
  •  
  • Sun StorageTek 9710 Tape Library
  •  
  • Sun StorageTek 9730 Tape Library
  •  
  • Sun StorageTek 9940 Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek L40 Tape Library
  •  
  • Sun StorageTek L5500 Tape Library
  •  
  • Sun Storage L1000 Tape Library
  •  
  • Sun Storage L1800 Tape Library
  •  
  • Sun Storage L400 Tape Library
  •  
  • Sun StorageTek 9740 Tape Library
  •  
  • Sun StorageTek L6000 Tape Library
  •  
  • Sun StorageTek 9840 Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek 9738 Tape Library
  •  
  • Sun StorageTek L80 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek 9714 Tape Library
  •  
  • Sun Storage L280 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun Storage L100 Tape Library
  •  
  • Sun StorageTek L20 Tape Library
  •  
  • Sun StorageTek SL48 Tape Library
  •  
  • Sun Storage L500 Tape Library
  •  
  • Sun Storage L11000 Tape Library
  •  
  • Sun Storage L8500 Tape Library
  •  
  • Sun Storage L25 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek SL24 Tape Autoloader
  •  
  • Sun StorageTek 9840D Tape Drive
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Drives - 9840
  •  
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  
  • GCS>Sun Microsystems>Storage - Tape>Libraries - 7400-Series
  •  
  • GCS>Sun Microsystems>Storage - Tape>Drives - T10000
  •  
  • GCS>Sun Microsystems>Storage - Tape>Drives - 9940
  •  
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  
  • GCS>Sun Microsystems>Storage - Tape>Libraries - 9700-Series
  •  

PreviouslyPublishedAs
227124


Applies to:

Sun StorageTek 9840 Tape Drive
Sun StorageTek 9840D Tape Drive
Sun StorageTek 9940B Tape Drive
Sun StorageTek 9940 Tape Drive
Sun StorageTek T10000A Tape Drive
All Platforms
Checked for relevance on 29-Dec-2010.

Goal

Information needed to troubleshoot a tape problem
Information needed to escalate issue
Tape troubleshooting
Escalation information
Library troubleshooting

Solution

Information needed to Escalate a Tape Problem to Support

Following is information needed to troubleshoot and escalate tape or library problems. Things required will vary depending on how involved the problem is and what product is being worked on.

(All information steps do not have to be provided on each case escalated)

1. Need Problem number from database: MOS (Required)
a. Exact error message: (Gather complete log which shows error)
b. Date of first occurrence:
c. Detailed account of events prior to the error:
d. Detailed description of actions taken since the detection of the error:
e. Severity:
f. Suspected device or devices:

2. Make, Model of all Tape drives and library: (Required)
a. Level of Microcode on the library
b. Level of Microcode on the tape device:
c. Fault Symptom Codes (FSCs) from STK Library:
d. Fault Symptom Codes (FSCs) from STK tape drives:
e. STK Library FSC or LMU logs:
f. Tape Drive Dumps, Logs and/or traces for tape drives:
i. DLT/SDLT Log page 7  Refer to Solution (See Internal Comments)
Refer to <Document: 1013576.1> for information to pull SDLT logs.
ii. 9840/9940 drive dump, event logs and/or perm logs
iii. Seagate/Quantum LTO using TapeRx.
Refer to <Document: 1015648.1> for information to pull Seagate/Quantum logs.
- Bezel Light combinations
iv. HP LTO logs using HP TAPE TOOLS.
Refer to <Document: 1013260.1> for information to pull HP logs.
- Bezel Light combinations
v. IBM LTO logs using NTUTIL or TAPEUTIL.
Refer to <Document: 1016763.1> for information to pull IBM logs.
- Number on LCD Panel
vi. T10000 logs using VOP.
Refer to <Document: 1013674.1> for information to pull T10000 logs.

3. Make, Model, and BIOS Level of Host Computer:

4. Tape Management Software and Revision (Backup or Archive application):
a. Gather complete tape logs showing error or backup failure

5. Operating System version and Patch listing or Service Pack Level:
a. Gather complete OS system logs and/or output from commands as dictated below.
Sun StorageTek SL48 Tape Library
Sun StorageTek Super-DLT220 Desktop Drive
Sun StorageTek T10000 Tape Drive Sun StorageTek SL48 Tape Library Sun StorageTek Super-DLT220 Desktop Drive
Sun StorageTek T10000 Tape Drive

Internal Comments

SL8500, 9940, 9840, audited, DLT, L1400, Information needed to troubleshoot a tape problem, SDLT, Information needed to escalate issue, Tape troubleshooting, Escalation information, Library troubleshooting, L20, L40, L80, T10000, L700, L180, LTO, SL500