Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1016817.1
Update Date:2011-05-11
Keywords:

Solution Type  Technical Instruction Sure

Solution  1016817.1 :   L180/L700 - Resetting Password in L-Series Library Administrator  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
227100


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: Confidential for Partners and Oracle Support personnel

Applies to:

Sun StorageTek L1400 Tape Library
Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
All Platforms
Checked for relevance on 11-May-2011.

Goal

Description
How to reset password on L-Series Library Admin.

Solution

Steps to Follow
Use the following instructions when the password cannot be remembered and the password needs to be reset for the L-Series Library Administrator:


1. Prior to resetting a password, make sure the password is not already at default of "horizon" (lower case) - should be displayed on Op Panel if this is the case.

2. Check the number of asterisks shown on the Op Panel as this may help in remembering the password i.e. ***** means password is 5 characters in length.

3. Should the above steps fail, the Oracle/StorageTek local support personnel will have to contact Level 2 Tape Hardware Support for further instructions on how to specifically Reset the password.

Note: The reason for this requirement is the instructions to 'Reset' the password are considered StorageTek Secret. This information is not to be used outside StorageTek Support Services and thus a Oracle/StorageTek CSE will be required on site to reset the password. The instructions will be provided verbally once Entitlements are verified.

This information is to be provided verbally only to Oracle/StorageTek Customer Support Personnel. To reset the Password, use the following instructions:


Internal Comments
Access to password reset information:

1. In the "cli" environment, enter: PASSWORD RESET cli responds with "please enter password"

2. Enter: *1* (asterisk one asterisk). The asterisks are required.

3. Cli will respond with DONE and the password is now HORIZON
password, L-Series Library Admin, resetL700, L180, Library Administrator, How to reset password on L-Series Library Administrator, Reset password, L-Series library, Instructions for Resetting Password in Step 3 above are accessible only by Level 2 Tape Hardware Support within this solution., Horizon, audited