Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1016628.1
Update Date:2011-05-09
Keywords:

Solution Type  Technical Instruction Sure

Solution  1016628.1 :   L180/700 - How to Enable or Disable Fast Load  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
226621


Applies to:

Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek L1400 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 9-May-2011.

Goal

How to Enable or Disable Fast Load

Some host software does not support the fast load enabled option.
Fast load on: The robot will mount a tape to a drive and then immediately report the move completed.

Fast load off: The robot will mount a tape to a drive and wait at the drive location until the tape is completely loaded before reporting the move completed.

Solution

Steps to Follow
At the Lib Config Menu:
  1. Arrow down to FAST LOAD
  2. Press Select
  3. Arrow to select either ON or OFF
  4. Press Select button to save changes. (You may press the MENU button to abort.)
  5. Press Menu is you haven't changed any other configuration or press Reset if you have changed other configuration options.