Solution Type  Technical Instruction Sure

Solution  1015815.1 :   L700/L180 - How to reset library statistics in Library Admin  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek L1400 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
224610


Applies to:

Sun StorageTek L180 Tape Library
Sun StorageTek L700 Tape Library
Sun StorageTek L1400 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 31-Jan-2011.

Goal

This article addresses how to reset library statistics in Library Admin.

Solution

Steps to Follow
To reset Library Statistics in Web Library Admin, you can go into the CLI port and do a "stat clear" command.

CLI>stat clear

This command is not available by the customer and must be done by a service representative.