Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1015604.1
Update Date:2011-01-19
Keywords:

Solution Type  Technical Instruction Sure

Solution  1015604.1 :   L700 - How To Set Hard Addressing in Library  


Related Items
  • Sun StorageTek L700 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - L-Series
  •  

PreviouslyPublishedAs
224083


Applies to:

Sun StorageTek L700 Tape Library
All Platforms
Checked for relevance on 19-Jan-2011.

Goal

How To Set Hard Addressing in L700e library.

Solution

This document describes L700 - How To Set Hard Addressing.
See page 3-12 of the L700E Operator's Guide.

Steps to Follow
How To Set Hard Addressing:
1. On L700e's operator panel, hit menu to access the main menu.
2. Path from main menu = Configuration -> Choose Drive -> Drive config, hit select.
3. Toggle Hard Addressing to ENABLED. Hard address will be set to 0.
4. Repeat for each drive that needs to use hard addressing.

NOTE:
This is also good for the L180 and L1400 library.


Fibre Channel, LTO, how, LTO, hard, addressing, enable, L700, Ultrium
Previously Published As STKKB50285

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback