Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1015266.1 : L20/L40/L80 - Troubleshooting the FC connectivity of L-Series libraries in HP environment
PreviouslyPublishedAs 223250
Applies to:Sun StorageTek L20 Tape LibrarySun StorageTek L40 Tape Library Sun StorageTek L80 Tape Library Sun StorageTek L700e Tape Library - Version: Not Applicable and later [Release: N/A and later] Sun StorageTek L180 Tape Library - Version: Not Applicable and later [Release: N/A and later] All Platforms Checked for relevance on 18-Jan-2011. GoalThis article troubleshoots the FC connectivity issues of L-Series libraries in a HP environment.SolutionSteps to FollowThe following is the process for troubleshooting the FC connectivity of L-Series libraries in HP environment: 1. Set the HARD ALPA on the library, must be unique ALPA in the SAN.
2. If the library is connected to a switch look at the Node List View on the switch if you can see the library. 3. Run ioscan -fn and identify the HP HBA in the example below it is /dev/fcms0:
fc 0 8/4 fcT1 CLAIMED INTERFACE HP Fibre Channel Mass Storage Adapter 4. Run fcmsutil /dev/fcms0 => Node/Port WWName, Topology 5. Ensure schgr driver is loaded: 6. Run ioscan fn and find the device name of the library: Class I H/W Path Driver S/W State H/W Type Description 7. The next command will produce a list of volumes in the library: HP-UX, FC Connection, Troubleshooting, Third party software has problem talking to the library, L20, L40, L80, How to troubleshoot Fibre Channel connectivity on L-series library in HP environment, HP environment, To get the full descriptions of the options for the used commands, run HP-UX man command, Fibre channel, L-Series libraries Previously Published As STKKB76405 Attachments This solution has no attachment |
||||||||||||
|