Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0All Platforms GoalCan a tape cartridge currently used as a MVC be be used as a "normal" tape?SolutionAnswer: Yes it can.MVCs are a standard formatted tape which is: Vol id HDR1 HDR2 TM DATA EOF1 EOF2 TM TM There are cautions in doing this. The data (VTVs) currently on the tape will be destroyed. Volser of the MVC must be removed from VTCS MVCPOOL statement. Tape should be reinitialized to set EOD marker to front of tape. Previously Published As STKKB16091 Attachments This solution has no attachment |
||||||||||||
|