Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1014769.1
Update Date:2011-05-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1014769.1 :   SL24/48 - How to Reset Admin and Service Password  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
  • Sun StorageTek SL24 Tape Autoloader
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
222017


Applies to:

Sun StorageTek SL24 Tape Autoloader
Sun StorageTek SL48 Tape Library
All Platforms
Checked for relevance on 15-Mar-2011.

Goal

How to Reset Admin and Service Password.

If you forget the administrator password, you cannot enter a new password. You must call your customer
service representative.

Solution

Steps to Follow
Customer is not able to reset passwords. A service representative will be required to do the reset.

Passwords can be reset via the RMI (Remote Management Interface), using the Service logon. The service logon password is 13572468. From there the access to the Configuration/restore defaults page can be made. The Admin password can be reset to null from this page.

Once you have logged into the RMI, select Configuration then Password to set Admin Password.

At this point you can set the Admin Password to the desired number, (enter exactly 8 numbers).

Once you have logged into the RMI, select Configuration then Restore Defaults to factory defaults or to restore Admin password to null.

NOTE:

The Account Types are:
• User — no password is required (leave the password box blank).
• Administrator — the administrator password is required. The same administrator password is used for the RMI and OCP (Operator Control Panel). There is not a default administrator password; the administrator password must be set with the OCP before it can be used with the RMI. If the administrator password is lost, contact Oracle Technical Support to generate a temporary password that will grant administrator access.
• Service —access to this level is by Service personnel only. The service password is set at the factory. The same service password is used for the RMI and OCP.
The user login provides access to the Identity and Status options, but not the Configuration, Operations, and Support options. Administrator level provides access to all screens except for the Log configuration and Service screens.

Refer to the SL24/48 Service and User Guide for further information.