Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1014752.1 : SL8500 - What Causes a Call Home Event on the SL8500?
PreviouslyPublishedAs 221993
Applies to:Sun StorageTek SL8500 Modular Library SystemAll Platforms Checked for relevance on 9-Feb-2011. GoalThis article addresses what causes a call home event on the SL8500.Service delivery platform SDP SolutionGeneric ERROR Events - Produce SNMP (level 1) traps.1101 Source Location Empty 1102 Drive Source Empty 1103 Destination Full 1104 Drive Destination Full 1105 Cartridge Label Miscompare 1106 Cartridge type not supported by drive 1107 Drive not unloaded for fetch 1108 Cap Door Open 1109 Cap Unlocked 1110 Cap already reserved 1111 Cap is in use 1112 Cap in use by another requester 1113 Storage element in use by another requester 1114 Cap is not online 1115 Library is not online 1116 Drive is not online 1117 Request is not cancelable 1118 No drive installed at address 1119 No cap magazine at address 1120 Drive doesn't support read only 1121 Internal device request timed out 1122 Elevator is not online 1123 Ptp is not online 1201 Missing parameter 1202 Request not found 1203 Too many values for parameter 1205 Invalid first parameter value 1206 Invalid second parameter value 1207 Invalid third parameter value 1208 Invalid fourth parameter value 1209 Invalid fifth parameter value 1210 Invalid start/end parameter pair 1211 Invalid address 1212 Invalid drive address 1213 No slot at address 1214 Device not found 1215 Library not found 1216 Drive not found 1217 Cap not found 1218 Request not found 1219 Request not currently supported by device 1308 Robot hand already contains a cartridge 1309 No cartridge in robot hand 1310 No operational hardware path to destination 1311 Drive reports empty after put 1312 Drive reports full after fetch 1313 Library hardware failure cartridge stranded! 1314 Catalog database failed 1315 Internal tracking of cartridge failed 1316 Remote library did not respond with source 1317 External send failed 1318 Remote library will not accept command transfer 1319 Robot operation failed 1320 Drive communication time-out 1321 Environmental hardware changed 3101 Could not load 3102 Schema file error 3103 SNMP MIB text file error 3202 File error 3204 System error 3206 Device response inconsistent 3207 Src and Dst not same rail 3208 Set library hardware failure 3209 Parameter not found in device response 3210 Not a valid number 3211 Source not found 3212 Destination not found 3213 Safety door move failed 3214 Invalid device type 3215 Robot initialization error 3216 User does not exist 3217 Permission for request denied 3218 Library online - test denied 3219 Device is online 3221 Host ip address error 3222 Host ip netmask error 3223 Host MAC address error 3224 Host name error 3225 System exception 3226 No version information found 3302 Test failure 3303 Device not operative 3304 Device robotic utility failure 3311 Address does not contain the cartridge 3312 Cartridge not found 3313 Cartridge range is not a valid range 3321 Robot not found 3322 Robot can not move beyond rail end 3323 Robot move failed 3324 Audit cannot complete due to hardware failure 3325 Third robot on rail 3331 Invalid drive address 3332 No compatible drives found in library 3333 Dropped unexpected device response 3334 Drive not in correct state for rewind unload 3335 Drive has misbuckle error 3336 Drive detected an expired clean cartridge - load retry not allowed 3341 Parameter is not a cap 3342 Cap not open 3344 Cap is unavailable 3351 Ptp not found 3361 Failure from safety door 3362 Safety door not found 3363 Safety door failure 3371 Elevator not found 3381 SNMP agent not found 3402 Error processing code version 3404 Reboot failed 3405 Download file write failed 3407 Manifest problem 3408 Firmware problem 3501 Change user failed 3502 Can not create requester 3503 Invalid requester 3621 Email id is not registered 3888 Library door is open 3889 ERS switch is pressed 3897 Cartridge remove failed 3905 Output packet dropped 3906 Input packet dropped 3910 Deserialization error 3954 Failure in send output 3955 Error from device 3984 Could not bind host socket 3985 Sax exception 3986 Sax parse exception 3987 Device io exception 3988 Communication time-out 3989 Device io format error 3991 Error in announce presence 3998 Security violation Steps to Follow Generic WARNING Events - Produce SNMP (level 2) traps 1204 No entries found 3205 Library in use 3220 The library id has been set and the library will be rebooted 3406 Code version applied 3811 Library started 3812 Device state changed 3819 Library configuration changed 3867 Safety door path not clear 3881 Library door opened 3882 Library door closed 3890 Safety door hardware warning 3891 Cartridge duplicate label found 3892 Cartridge not in expected location 3893 Cartridge unexpectedly discovered 3894 Cartridge found doesn't match catalog 3911 ILC socket closed 3912 HLI connection status change 3983 PLI socket closed without cancel 3992 Warning from device 3996 Access door opened/closed in CSE mode 3999 Device listener stopped SDP, Traps, Trap Information, What causes call home on the SL8500, SL8500, What types of events causes SL8500 SNMP traps, What causes the SL8500 to call home Previously Published As STKKB80705 Attachments This solution has no attachment |
||||||||||||
|