Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1014665.1
Update Date:2011-05-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1014665.1 :   SVA - What are the restrictions when defining FlexVolumes in the V2X4f?  


Related Items
  • Sun StorageTek V2X SVA Disk System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
  •  

PreviouslyPublishedAs
221762


Applies to:

Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable - Release: N/A to N/A
All Platforms
Reviewed for currency 05/20/11

Goal

List the restrictions on defining FlexVolumes on the V2X4F

Solution

For a 3380 track format, the valid virtual device types are:

- 3380 J for cylinder counts 1 through 885.
- 3380 KE for cylinder counts 886 through 1770
- 3380 K for cylinder counts 1771 through 2655

For a 3390 track format, the valid virtual device types are:
- 3390 Mod 3 for cylinder counts 1 through 3339
- 3390 Mod 9 for cylinder counts 3340 through 10,017