Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1014249.1
Update Date:2011-01-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1014249.1 :   C4 - Fixed Cell Cartridge Replacement and Audit Information  


Related Items
  • Sun Storage C4 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - C-Series
  •  

PreviouslyPublishedAs
220670


Applies to:

Sun Storage C4 Tape Library
All Platforms
Checked for relevance on 4-Jan-2011.

Goal

This article addresses fixed-cell cartridge replacement and audit information.

Can cartridges be manually replaced from fixed cells?

Are fixed cells inventoried during cell inventory?

Solution

Steps to Follow
Manually changing the tape cartridges out of the two fixed cells in the C4 library is NOT recommended due to the potential of damaging the robotics when reaching in and out of the library.  The fixed cells were not designed to be accessed manually.
When the 'Inventory Full' option is enabled on the OCP panel, the robotics will appear to inventory the two fixed cells.  In reality, the code is not updating the inventory data base. The 'Inventory Full' option was only intended for use on the Load Ports and Magazines, NOT for the fixed cells.

This was addressed in C4 code release above V26.



@ Fixed cell cartridge, Manual replacement of cartridges in fixed cell, Manual replacement, Inventory full option, Cell inventory, C4