Solution Type Technical Instruction Sure Solution 1014235.1 : L180/700/1400 - 3.13.01 Code Supports 8 Characters in the SCSI VOLID Field
PreviouslyPublishedAs 220645
Applies to:Sun StorageTek L1400 Tape LibrarySun StorageTek L180 Tape Library Sun StorageTek L700 Tape Library All Platforms Checked for relevance on 18-Jan-2011. Goal3.13.01 Code Supports 8 Characters in the SCSI VOLID Field.SolutionSteps to FollowProduct Enhancements 1. Added support for 8 character SDLT labels with media domain/types of S1, S2, S3, S4.
* Note - Library Engineering verified with code writer - that this is full support for all drives attached to the L180/700/1400 series, not just SDLT.
2. Added new CLI label-option command to support sending all characters read in the VOLID label in the SCSI VOLID field, and be able to specify if the media domain/type characters should be a prefix or suffix to the VOLID.
The new command syntax is:
As of 3.13.01 the L700/180 can report 6 or 8 characters in the SCSI VOLID field, not 7, 9, or up to 12.
Then "label-option off" places 123456 in the SCSVI VOLID field. Then "label-option before" places L1123456 in the SCSVI VOLID field. Then "label-option after" places 123456L1 in the SCSVI VOLID field. VOLID, With release of code 3.13.01 the L180/700/1400 series can report 6 or 8 characters in the SCSI VOLID field., L1400, L700, L180, Barcode labels, Support, 8 character support for volser labels, Code 3.13.01, Volser, audited, 8 Character Previously Published As STKKB78281 Attachments This solution has no attachment |
||||||||||||
|