Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1014178.1
Update Date:2011-03-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1014178.1 :   VTL - How to replace a failed physical drive attached to VTL server  


Related Items
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Storage Appliance
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
220532
What is the procedure to replace a failed physical drive attached to VTL server for Automated Tape Caching (ATC) or exports.

Applies to:

Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656 - Release: 1.0 to 2.0
Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 to 4.0 - Build 1221   [Release: 4.0 to 4.0]
Information in this document applies to any platform.

Goal

Provide customers and Oracle field support with procedure for replacing a physical tape drive attached to backend of VTL server.

Solution

Procedure to replace a failed physical drive:
  1. Verify the failed physical tape drive is not in use: there aren't migrations virtual-to-physical, direct access, etc...
  2. Unassign the failed physical tape drive under the Physical Tape Library tree in the VTL Console GUI.
  3. Discharge the failed physical tape drive on the HBA to delete all references to wwpn, serial number and ACSLS position of the failed tape drive. Doing this discharge, you will avoid restart VTL Service.
  4. Replace the failed physical tape drive: the new tape drive will have new wwpn and new serial number.
  5.  If ACSLS is in configuration, reconfigure ACSLS database to update the new parameters from the new physical tape drive (wwpn, serial number): /"config drive panel_id/" where panel_id for L700 will be 0,0,0.
    Note: Doing this reconfiguration, you will avoid restarting ACSLS.
  6. Rescan the HBA via VTL Console GUI
  7. Enlist the new physical tape drive.
  8. Assign the new physical tape drive on the physical tape library (the new physical tape drive will now have new wwpn, new serial number and same ACSLS position).





================================