Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1014164.1
Update Date:2011-02-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1014164.1 :   SL8500 - How to Reset Passwords on Library  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - SL-Series
  •  

PreviouslyPublishedAs
220509


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: confidential for Partners and Oracle Service Personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 4-Feb-2011.

Goal

Password no longer works or has been forgotten by user.
How to reset password for OEM Environment
How to reset password for Admin Environment
How to reset password for Service Environment
How to reset password on Op Panel

Solution

Advance Service Password can not be reset in the field. Only OEM, Service, and Admin and op panel passwords can be changed.

For now, the password cannot be reset under admin as it can not log into CLI with admin login after it is activated < Document: 1017161.1 >

Steps to Follow
This function does not work for Advance Service Password, it is not field resetable.
Prerequisites:

  • Code 3.08 or higher.
  • You must be in the CLI port.
  • You must have activated a password.

Syntax:

resetPassword
where user is admin,oem,service, or all

Places the specified login password back to the "needs activated" state. This is used to recover forgotten passwords.