Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1013571.1
Update Date:2011-05-20
Keywords:

Solution Type  Technical Instruction Sure

Solution  1013571.1 :   SVA - What is the maximum number of virtual devices supported by the V2X4f?  


Related Items
  • Sun StorageTek VSM System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk - Other
  •  

PreviouslyPublishedAs
219096


Applies to:

Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0
All Platforms
Update for currency 5/20/11

Goal

What is the maximum number of virtual devices supported by the V2X4f?

Solution

There are constraints to the 4096 number:
  • 3390-3 FlexVolume must not exceed 3,339 cylinders.
  • A 3390-9 FlexVolume must not exceed 10,017 cylinders.
  • A 3390-9 Large volume must not exceed 32,760 cylinders.


Steps to Follow
The maximum number of virtual devices is 4096.
This is the same as the V2X product.