Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1013077.1 : Validating Sun StorEdge[TM] 6920 Virtual Disk Deletion
PreviouslyPublishedAs 217914
Applies to:Sun Storage 6920 SystemAll Platforms GoalThe purpose of this document is to provide basic steps for virtual disk (vdisk) deletion for the 6920 array, via the Browser User Interface(BUI) or sscs Command Line Interface(CLI). Content will be limited to a basic usage using the CLI or BUI interfaces for deleting vdisks, and provide help with some usage failure scenarios for this activity. Consider reviewing some of the following documents if you are looking to perform actions beyond the scope of this document:
Solution1. Validate if the Virtual Disk is in use.
Make sure that the virtual disk details via SSCS shows nothing in Associated Volumes field, or the State field in the BUI shows Not In Use. Reference <Document 1002889.1> Validating VDisk State and Details on a Sun StorEdge[TM] 6920:
2. Basic Usage Using Browser or SSCS interfaces. SSCS Virtual Disk deletion usage for sscs, can be reviewed in the Sun StorEdge 6920 System CLI Quick Reference Guide, Release 3.0. The sscs usage for basic virtual disk deletion is as follows. sscs delete vdisk An example: sscs delete vdisk disk/1/8/0/3/0 This will delete the virtual disk called disk/1/8/0/3/0.
NOTE: The Storage Domain is assumed to be DEFAULT when it is not specified by the -S switch in the usage.
BUI Virtual Disk Deletion steps for the BUI can be reviewed in Sun StorEdge 6920 System Administration Guide For the Browser Interface Management Software, Release 3.0 for help with other object deletion activities. Virtual Disk deletion for the BUI interface of the 6920 is completed as follows:
At this point the Pop-Up window will disappear, and the main browser screen will refresh, and a success or failure message will be displayed in the Virtual Disks Summary page. The virtual disk will no longer be listed.
3. Deletion Failure. Please review the following table for a failure message and corresponding action. Please follow the action that describes your symptom.
BUI
An error occurred. Please contact your system administrator Action:
SSCS
Error: The operation failed Action: Message: Item is in use: ; operation failed. Action: Message: : The object was not found Action: Message: No Virtual Disk Manager
Action: If a message is not listed, or an action above did not work, go to Step 4. 4. Data Collection Please collect the following information:
sscs list sdomain
NOTE: Screen captures of the summary page for each object could be used, as well, for BUI related creations.
Once this information is collected, please contact the Oracle Support. Attachments This solution has no attachment |
||||||||||||
|