Solution  1012980.1 :   Sun SPARC(R) Enterprise Mx000 (OPL) Servers: snapshot "Unable to mount USB device"  


Related Items
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M8000 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
217778


Description
After inserting a USB memory stick into the maintenance port of an OPL XSCF, snapshot reported that it is unable to mount the USB device.

Steps to Follow
Sun SPARC� Enterprise Mx000 (OPL) Servers: snapshot "Unable to mount USB device".

The snapshot command expects the USB device to have a partition 1 with a fat32 filesystem. (/dev/sda1) If your device does not have any partitions, the XSCF will see your USB memory stick as /dev/sda. Without the partition snapshot will not be able to mount the device correctly and report "Unable to mount USB device".
To create a partition table on your USB stick, you can plug your USB memory stick into a Windows Computer, which should re-partition and format the device with one large partition as a FAT32 file system.

Update:
This issue is fixed in XCP 1050.

Product
Sun SPARC Enterprise M3000 Server
Sun SPARC Enterprise M4000 Server
Sun SPARC Enterprise M5000 Server
Sun SPARC Enterprise M8000 Server
Sun SPARC Enterprise M9000 Server
Sun SPARC Enterprise M9000-32 Server
Sun SPARC Enterprise M9000-64 Server

Internal Comments
For the use of Sun Microsystems employees:

See change request http://monaco.sfbay/detail.jsf?cr=6531640 for more information.

OPL, snapshot

Previously Published As
88601

Change History
Date: 03 Nov 2009
User Name: Cootware
Action: Added fix information to public section and bug info to internal section

2009-11-04: Volkmar Grote - added M3000

Date: 03 Nov 2009
User Name: Cootware
Action: Added fix information to public section and bug info to internal section


Verified still correct for audience - currently set to contract
Audience left at contract as per FvF at
http://kmo.central/howto/content/voyager-contributor-standards.html
Checked review date - currently set to 2008-02-22
Checked for TM - ok as presented
Publishing under the current publication rules of 18 Apr 2005:
Version: 4


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback