Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012811.1
Update Date:2010-12-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012811.1 :   C4 - Tape Library , Load Errors due to Defective Magazines  


Related Items
  • Sun Storage C4 Tape Library
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Tape>Libraries - C-Series
  •  

PreviouslyPublishedAs
217591


Applies to:

Sun Storage C4 Tape Library - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Reviewed for relevance on 23-Dec-2010.

Goal

Older Oracle/StorageTek[TM] C4 Tape Libraries have a defective tape storage magazine that causes tapes to not be completely inserted into the storage slot.

When that happens the robot can hit the projecting tape and derail.

Solution

Steps to Follow
The magazine detent force in some early Oracle/StorageTek C4 Tape Library products is too high causing it to get (2212) and put (2281) errors. When this happens the tapes can get dropped by the hand, or not inserted fully into the tape magazine.
Impact

The impact is low, as no customer data is affected and the probability of this happening is relatively low.

Remedial Actions

The vendor modified the Oracle/StorageTek C4 Tape Library firmware in revision V14 to better handle excessive magazine detent force.  Be sure units in the field have revision V14 or greater installed.

Second, replace the tape magazine if it is not up to current specifications.  Any magazine without a serial number label is not up to current specifications and could be subject to this issue. See the attached picture for a photo of a magazine with the serial number that indicates it is a current version. Order the below parts depending on the tape drive in use:

SG-XMAGLTO-C-Z 380-1392 LTO Magazine (18-cartridge slots)

SG-XMAGSDLT-C-Z 380-1393 SDLT Magazine (15-cartridge slots)

Dates Effected

The vendor has modified the magazine racks to correct the issue starting in March 2006.

Known failures were built in February 2006 or before.



Internal Comments
See PLC-IMS #5970 links section for firmware installation instructions.
c4, magazine, 2212, 2281, firmware, hung tape
Previously Published As
88859