Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1012612.1 : Sun StorEdge [TM] 9900 - A SIM on the SVP is not seen on Storage Navigator
PreviouslyPublishedAs 217359 Description A SIM is reported to the SVP, yet Storage Navigator does not list the SIM. Steps to Follow SVP = Service Processor In order for a SIM to be sent to Storage Navigator, it has to be deemed as "reported to the host". In other words, there will be some SIMs (on the SVP) that WILL NOT be seen via Storage Navigator. (Reference: TagmaStore USP Storage Navigator User?s Guide, MK-94RD206-01, section 3.1.3 Storage Navigator Main Panel, Status Tab. 9900V Remote Console Storage Navigator User's Guide, MK-92RD101-13, section 3.1.2 Storage Navigator Main Panel, Status Tab. See the Note after the first paragraph in the section.) To find out which SIMS are/are not reported to the host, see the 9985, 9900V and 9990 SIM RC Maintenance Manual. Section 2.2 lists the "SIM Reference Codes detected by the SVP". Take a look at the "host report" column. If it says "no", then the SIM will not Product Sun StorageTek 9900V Series Array Sun StorageTek 9960 System Sun StorageTek 9910 Sun StorageTek 9990 NAS Blade Sun StorageTek 9985 System Sun StorageTek 9970 System Sun StorageTek 9990 System Internal Comments This is documented similarly on the HDS ChannelOne website, Solution ID HDS43171. However, I've seen it discussed enough on the bigfish alias often enough that an info doc. is necessary. This was illustrated in ESC 1-7516747.
The link to 99xx maintenance manuals is: SIM, reported, storage, navigator, report, host Previously Published As 83117 Change History Date: 2005-11-07 User Name: 38429 Action: Created Comment: Version: 0 Product_uuid f55c65ae-16a0-11d7-82ad-99701a4c6e31|Sun StorageTek 9900V Series Array 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 00c65c11-ae1b-11d9-9adf-080020a9ed93|Sun StorageTek 9990 NAS Blade 73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System 15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System Attachments This solution has no attachment |
||||||||||||
|